15. SERVO AMPLIFIER CONNECTION
15.5 Setting on Servo Amplifier Side
15 - 15
SER
VO AMPLIFIER CONNECTION
15
15.5.2
Connecting to the
MELSERVO-J2M Series
POINT
POINT
POINT
MELSERVO-J2M Series
For details of the MELSERVO-J2M Series, refer to the
following manual.
MELSERVO-J2M Series Servo Amplifier
Instruction Manual
Parameter of MELSERVO-J2M Series
Enter the parameters of the MELSERVO-J2M Series.
*1
Specify the same transmission speed as that of the GOT.
For the transmission speed setting on the GOT side, refer to
the following.
15.4.1 Setting communication interface
(Communication settings)
*2
Avoid duplication of the station No. with any of the other
units.
POINT
POINT
POINT
(1) Parameter setting
Set the parameter at the pushbutton switch
provided on the operation section of the servo
amplifier or setup software.
(2) When changing the parameter
Turn off then on the servo amplifier to be effective
the new parameter.
Item
Set value
Basic IFU parameter
No. 0
Serial communication function selection
(Default: 0000)
(1) Serial communication baud rate selection
*1
0: 9600bps
1: 19200bps
2: 38400bps
3: 57600bps
(2) Serial communication I/F selection
0: RS-232
1: RS-422
(3) Communication response delay time
selection
0: Invalid
1: Valid (Response after 800
s or longer
delay)
Basic IFU parameter
No. 10
Interface unit serial communication station No.
selection:
0 to 31 (Default: 0)
*2
Basic IFU parameter
No. 11
Slot 1 serial communication station No. selection:
0 to 31 (Default: 1)
*2
Basic IFU parameter
No. 12
Slot 2 serial communication station No. selection:
0 to 31 (Default: 2)
*2
Basic IFU parameter
No. 13
Slot 3 serial communication station No. selection:
0 to 31 (Default: 3)
*2
Basic IFU parameter
No. 14
Slot 4 serial communication station No. selection:
0 to 31 (Default: 4)
*2
Basic IFU parameter
No. 15
Slot 5 serial communication station No. selection:
0 to 31 (Default: 5)
*2
Basic IFU parameter
No. 16
Slot 6 serial communication station No. selection:
0 to 31 (Default: 6)
*2
Basic IFU parameter
No. 17
Slot 7 serial communication station No. selection:
0 to 31 (Default: 7)
*2
Basic IFU parameter
No. 18
Slot 8 serial communication station No. selection:
0 to 31 (Default: 8)
*2
Basic IFU parameter No. 0
0
(3) (2)
(1)
MODE
UP
DOWN
SET
Pushbutton switch
provided on the operation
section of the servo amplifier
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......