14. INVERTER CONNECTION
14.3 Connection Diagram
14.3 Connection Diagram
The following diagram shows the connection between the
GOT and the inverter.
14.3.1
RS-485 cable
Connection diagram
(1) RS485 connection diagram 1)
*1
Set the terminating resistor to "Disable".
1.4.3 Terminating resistors of GOT
(2) RS485 connection diagram 2)
*1
Connect a terminating resistor jumper to RDB and
RDR.The terminating resister jumper is packed together
with the FR-A5NR.
*2
Set the terminating resistor to "Disable".
1.4.3 Terminating resistors of GOT
GOT side
*1
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
5
4
3
6
2
8
-
-
1
2
7
1
6
3
8
4
9
5
-
SDA
SDB
RDA
RDB
P5S
P5S
-
-
SG
Inverter or Distributor side
(Modular connector)
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
2
7
1
6
3
8
4
9
5
-
SDA
SDB
RDA
RDB
RDR
SG
FR-A5NR side
(terminal block)
*1
GOT side
*2
(3) RS485 connection diagram 3)
SDA
SDB
RDA
RDB
P5S
P5S
SG
5
4
3
6
2
8
1
5
4
3
6
2
8
1
SDA
SDB
RDA
RDB
P5S
P5S
SG
Inverter side or distributor side
(Modular connector)
Distributor side
(Modular connector)
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......