Appendix A: LIST OF PARAMETERS AND DATA
Appendix A-5 Servo Parameters List
290
FX
3U
-20SSC-H Positioning Block User's Manual
BFM
#15076
BFM
#15276
Analog monitor feedback
position output standard
data Low
(Ver. 1.40 or later)
Setting of standard position of feedback output with analog
monitor 1 (MO1) or 2 (MO2)
K0
Subsection 11.2.3
BFM
#15077
BFM
#15277
Analog monitor feedback
position output standard
data High
(Ver. 1.40 or later)
Setting of standard position of feedback output with analog
monitor 1 (MO1) or 2 (MO2)
K0
BFM
#15080
BFM
#15280
Function selection C-4
Select the home position setting condition in the absolute
position detection system
K1
BFM
#15083
BFM
#15283
Function selection C-7
(Ver. 1.40 or later)
Setting when undervoltage alarm occurs
H0000
BFM
#15084
BFM
#15284
Alarm history clear
(Ver. 1.40 or later)
Used to clear the alarm history
H0000
BFM
#15087
BFM
#15287
Forced stop deceleration
time constant
(Ver. 1.40 or later)
Only the MR-J3-
BS
Setting of deceleration time constant for forced stop
deceleration
H0000
BFM
#15094
BFM
#15294
Vertical axis freefall
prevention
compensation amount
(Ver. 1.40 or later)
Only the MR-J3-
BS
Setting of compensation amount of the vertical axis freefall
prevention function
H0000
BFM
#15102
BFM
#15302
Output signal device
Selection 1 (CN3-13)
Setting of output signal to the connector (CN3-13 pin) of servo
amplifier
H0005
Subsection 11.2.4
BFM
#15103
BFM
#15303
Output signal device
Selection 2 (CN3-9)
Setting of output signal to the connector (CN3-9 pin) of servo
amplifier
H0004
BFM
#15104
BFM
#15304
Output signal device
Selection 3 (CN3-15)
Setting of output signal to the connector (CN3-15 pin) of servo
amplifier
H0003
BFM
#15109
BFM
#15309
Function selection D-3
(Ver. 1.40 or later)
Selects the ALM output signal at warning occurrence.
H0000
BFM number
Item
Settings
Default
value
Reference
X axis