Appendix A: LIST OF PARAMETERS AND DATA
Appendix A-2 Control Data Table
283
FX
3U
-20SSC-H Positioning Block User's Manual
11
Buffer
M
e
m
o
ry
12
Pr
ogr
am
Exam
ple
13
D
iagnostics
A
List
of
Par
a
m
e
ter
s and
Da
ta
B
V
e
rs
ion
Infor
m
at
ion
*1.
For details on the user units, refer to the section given below.
→
Refer to Section 7.10
*2.
-2,147,483,648 to 2,147,483,647 with Variable Speed operation.
*3.
BFM #618 b10 is not available.
*4.
BFM #619 b1 is not available.
BFM #521
BFM #621
Table operation start
number
0 to 299
K0
Subsection 11.4.13
BFM #522
Control command
enable/disable
Model code: control command enabled
Other than model code: control command disabled
K0
Subsection 11.4.14
BFM #523
Control command
b0
Stores positioning parameters of X axis (BFM#14000 to
BFM #14199) to flash memory
b1
Stores positioning parameters of Y axis(BFM#14200 to
BFM #14399) to flash memory
b2
Stores table information of X axis (BFM #1000 to
BFM #3999) to flash memory
b3
Stores table information of Y axis (BFM #4000 to
BFM #6999) to flash memory
b4
Stores table information of XY axes (BFM #7000 to
BFM #12999) to flash memory
b5
Stores servo parameters of X axis (BFM #15000 to
BFM #15199) to flash memory
b6
Stores servo parameters of Y axis (BFM #15200 to
BFM #15399) to flash memory
b7
Not available
b8
Initializes positioning parameters of X axis (BFM #14000 to
BFM #14199)
b9
Initializes positioning parameters of Y axis (BFM #14200 to
BFM #14399)
b10 Initializes table information of X axis (BFM #1000 to
BFM #3999)
b11 Initializes table information of Y axis (BFM #4000 to
BFM #6999)
b12 Initializes table information of XY axes (BFM #7000 to
BFM #12999)
b13 Initializes servo parameters of X axis (BFM #15000 to
BFM #15199)
b14 Initializes servo parameters of Y axis (BFM #15200 to
BFM #15399)
b15 Not available
H0000
Subsection 11.4.15
BFM
#525,#524
BFM
#625,#624
Manual pulse input
magnification
(numerator)
1 to 1,000,000 times
K1
Subsection 11.4.16
BFM
#527,#526
BFM
#627,#626
Manual pulse input
magnification
(denominator)
1 to 1,000,000 times
K1
Subsection 11.4.17
BFM #528
BFM #628
MPG response
(Ver. 1.10 or later)
1 to 32767
K4
Subsection 11.4.18
BFM #529
MPG input selection
(Ver. 1.10 or later)
0: X input - X opr / Y input - Y opr
1: X input - Y opr
2: X input - X and Y opr
K0
Subsection 11.4.19
BFM #530
BFM #630
Ring operation rotation
direction for absolute
address
(Ver. 1.10 or later)
0: Direction for shorter rotation
1: Direction where the current value increases (clockwise)
2: Direction where the current value decreases
(counterclockwise)
K0
Subsection 11.4.20
BFM number
Item
Description/Setting range
Default
value
Reference
X axis
Y axis