11 Buffer Memory (Parameters & Monitored Data)
11.1 Positioning Parameters
209
FX
3U
-20SSC-H Positioning Block User's Manual
11
Buffer
M
e
m
o
ry
12
Pr
ogr
am
Exam
ple
13
D
iagnostics
A
List
of
Par
a
m
e
ter
s and
Da
ta
B
V
e
rs
ion
Infor
m
at
ion
11.1.8
Acceleration time [BFM #14018, BFM #14218]
This parameter sets a time for the operation speed to reach the maximum speed from zero.
In a 20SSC-H Ver. 1.30 or later, "acceleration time" and "acceleration time 2" are offered as the acceleration
time except for interpolation operation. Use the acceleration/deceleration time change command in operation
command 2 to select acceleration time or acceleration time 2 to be used for actual positioning operation.
→
For details on the acceleration time, refer to Section 7.2
→
For setting of the acceleration time 2, refer to Subsection 11.1.25
→
For changeover of the acceleration/deceleration time, refer to Section 7.7
Note
• The acceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when set at 5001
ms or more.
• Set the time within the range from 64 (greater than 64) to 5000 ms in the approximate S-shaped
acceleration/deceleration.
11.1.9
Deceleration time [BFM #14020, BFM #14220]
This parameter sets the time for the operation speed to reach zero from the maximum.
In a 20SSC-H Ver. 1.30 or later, "deceleration time" and "deceleration time 2" are offered as the acceleration
time except for interpolation operation. Use the acceleration/deceleration time change command in operation
command 2 to select deceleration time or deceleration time 2 to be used for actual positioning operation.
→
For details on the deceleration time, refer to Section 7.2
→
For setting of the deceleration time 2, refer to Subsection 11.1.26
→
For changeover of the acceleration/deceleration time, refer to Section 7.7
Note
• The acceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when set at 5001
ms or more.
• Set the time within the range from 64 (greater than 64) to 5000 ms in the approximate S-shaped
acceleration/deceleration.
11.1.10 Interpolation time constant [BFM #14022, BFM #14222]
This parameter sets the time to reach the operation speed from zero (acceleration) or to reach zero from the
operation speed (deceleration).
→
For details on the interpolation time constant, refer to Section 7.2
Note
The acceleration time becomes 1 ms when set at 0 ms or less, and becomes 5000 ms when set at 5001 ms
or more.
BFM Number
Description
Default
X-axis
Y-axis
BFM #14018
BFM #14218
Setting range: 1 to 5000 ms
K200
BFM Number
Description
Default
X-axis
Y-axis
BFM #14020
BFM #14220
Setting range: 1 to 5000 ms
K200
BFM Number
Description
Default
X-axis
Y-axis
BFM #14022
BFM #14222
Setting range: 1 to 5000 ms
K100