FX
3U
Series Programmable Controllers
User's Manual - Hardware Edition
76
5 Version Information and Peripheral Equipment Connectability
5.1 Version Upgrade History
5.1.2
Version check method
In FX
3U
PLCs, users can obtain the PLC version information by monitoring special data register D8001
(decimal number), or the PLC version can be checked in "PLC Status" in the display module.
→
For the operating procedure of the display module,
refer to Chapter 19.
5.1.3
Version upgrade history
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver. 2.20
55****
(May, 2005)
First product
Corresponds to FX
3UC
PLC Ver. 2.20.
Ver. 2.30
5Y****
(November, 2005)
The following instructions are added or their functions are enhanced:
MEP and MEF instructions are added.
The functions of the MUL (FNC 22), DIV (FNC 23) and RS2 (FNC 87) instructions are
enhanced.
Ver. 2.41
7Y****
(November, 2007)
The functions of the following instructions are enhanced:
The baud rate "38400 bps" is supported in RS and RS2 instructions, inverter
communication instructions and computer link.
Ver. 2.61
97****
(July, 2009)
• Support of the following 6 instructions:
FLCRT (FNC300), FLDEL (FNC301), FLWR (FNC302), FLRD (FNC303),
FLCMD (FNC304), FLSTRD (FNC305)
• Supports customer keyword and permanent PLC lock.
• Supports connection of following special adapters:
- FX
3U
-3A-ADP
- FX
3U
-CF-ADP
• Supports the hardware error function of FX
3U
-4DA-ADP.
Ver. 2.70
107****
(July, 2010)
• Support of the following 3 instructions:
VRRD (FNC 85), VRSC (FNC 86), IVMC (FNC275)
• Supports connection of following analog volume expansion board:
- FX
3U
-8AV-BD
• Supports the under-scale detection function of the FX
3U
-4AD-ADP and FX
3U
-
3A-ADP.
Ver. 3.00
115****
(May, 2011)
• Supports storage of symbolic information.
• Supports the setting "Read-protect the execution program." for block
passwords.
• Special block error condition (D8166) is added.
• Supports connection of following memory cassette:
- FX
3U
-FLROM-1M
Ver. 3.10
11Y****
(November, 2011)
• Supports the following functions of the FX
3U
-16CCL-M:
- Network parameter
- Accessing the other station from CC-Link
- Remote device station initialization procedure registration
- CC-Link diagnostics
• Special parameter error (M8489 and D8489) is added.
D8001
PLC type and
version
2
4
2
2
0
Version information (Example: Ver. 2.20)
PLC type (Example: 24 = FX
2N
/FX
2NC
/FX
3U
/FX
3UC
PLC)