FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
95
6 Examination of System Configuration
6.3 Number of Input/Output Points and Maximum Number of Input/Output Points
1
Introducti
on
2
Features
and
Par
t Names
3
Product
Introduc
tion
4
Sp
eci
fic
ati
ons
5
V
ers
ion and
Peri
ph
er
al
D
evices
6
S
yst
em
C
onfi
guration
7
Input/Ou
tput
No
s., Un
it No
s.
8
Inst
allati
on
9
Prep
arati
on an
d
Pow
er Supp
ly
Wi
rin
g
10
Input W
iring
6.3.2
Maximum number of input/output points when CC-Link master is used
1. Calculation of maximum number of input/output points
When CC-Link master block is used, the following maximum number of input/output points can be connected.
*1.
224 points when the FX
2N
-16CCL-M is used.
The number of CC-Link points is calculated by the formula "32 points
×
number of stations" even when
remote I/O stations having less than 32 points are used.
For details, refer to the manual of the CC-Link master block used.
2. Procedures for calculating number of input/output points based on example of system
configuration
For the main unit, input/output powered extension units/blocks and CC-Link remote I/O stations, the number
of input/output points and the total number of points are restricted.
≥
Maximum number of
input/output points
384 points
Maximum number
of points
controllable on
system
Number of input/
output points
+
Total number of
input/output points
(A)(B)(C)(D)
Number of input/output
occupied points
(E) units
Number of points
occupied by special
function units/blocks
+
CC-Link remote I/O
(F) stations
Total number of points obtained by formula
"number of remote I/O stations
*1
(The number is multiplied by 32 points
32 points"
regardless of the number of remote I/O points.)
For details, refer to Subsection 6.3.1.
(A): Number of input/output points of main unit
(B): Number of input/output points of input/output
powered extension units
(C): Number of input/output points of input/output
extension blocks
(D): Number of remote I/O points of FX
2N
-64CL-M or FX
2N
-
16LNK-M
(E): Number of input/output points occupied by special
function units/blocks
(F): Number of remote I/O stations (units) connected to CC-
Link master
×
8
points
×
32
points
256
points
≤
×
−
−
Special
function unit
−
−
FX
3U
-16CCL-M
Input
extension
block
X000 to X027
Y000 to Y027
Main unit
X030 to X057
Y030 to Y057
Input/output
powered
extension unit
X060 to X077
−
Input
extension
block
8 points
24/24
= 48 points
X100 to X117
−
CC-Link network
Remote I/O
(8 points)
Remote I/O
(16 points)
Remote I/O
(32 points)
Remote I/O
(32 points)
Remote I/O
(32 points)
Number of
remaining points
Number of input/output points (128 points)
0 points
384 points
128
224 256
160
144
32 points
×
5 units = 160 points
Number of
remaining points
Number of input/output points (excluding remote I/O points on CC-Link) + Number of
input/output occupied points
Up to 256 points
Number of input/output points occupied by special function units/blocks
Number of CC-Link input/output points
Up to 256 points
384 points or less in total
24/24
= 48 points
16/0
= 16 points
16/0
= 16 points
8 points
Summary of Contents for FX2-16E series