Mitsubishi FX1N-485-BD User Manual Download Page 1

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any 
patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving 
industrial property rights which may occur as a result of using the contents noted in this manual.

HEAD OFFICE
HIMEJI WORKS

 : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
 : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

Side

B

FX

1N

-485-BD RS-485 COMMUNICATION BOARD

USER’S GUIDE

JY992D84201C

This manual only describes the specifications for RS-485 Communication Board FX

1N

-485-BD.

For complete operation, wiring, mounting and programming instructions please refer to the FX

1S

, FX

1N

HARDWARE MANUAL and PROGRAMMING MANUAL.
These manuals should be read and understood before attempting to install or use the unit.

Associated Manuals

1. Outline of Product

The RS-485 communication board FX

1N

-485-BD (hereafter referred to as "485BD") is connected to the

FX

1S

/FX

1N

 Series PLC basic unit, and available for the applications described below.

Only one function expansion board can be connected to one PLC basic unit. Accordingly, the 485BD cannot
be used together with the FX

1N

-422-BD or the FX

1N

-232-BD.

1.1 Features

1) No protocol communication.

The 485BD transfers the data using the RS instruction between a bar code reader, personal computer
or printer.
As the 485BD is not equipped with buffer memory, it sends and receives the data using data registers
specified by the RS instruction.
For the RS instruction and the communication setting, refer to the FX Series User's Manual - Data
Communication Edition.

2) Computer link by dedicated protocol.

The 485BD transfers the data when a personal computer directly specifies devices of the PLC.
For the dedicated protocol and the communication setting, refer to the FX Series User's Manual - Data
Communication Edition.

3) Parallel link.

The 485BD transfers automatically auxiliary relays and data registers when two FX

1S

 Series PLC’s or

two FX

1N

 Series PLC’s are connected on a one-to-one basis.

For the setting procedure and program examples, refer to the FX Series User's Manual - Data Commu-
nication Edition.

4) N:N network.

The 485BD transfers automatically up to 64 auxiliary relays and 8 data registers when up to eight FX

1S

/

FX

1N

 Series PLC units are connected. For the setting procedure and program examples, refer to the

FX Series User's Manual - Data Communication Edition. 

Manual name

Manual No.

Description

FX

1S

 Series

Hardware Manual

JY992D83901

Describes contents related to hardware of FX

1S

 Series PLC such 

as specifications, wiring and installation.

FX

1N

 Series 

Hardware Manual

JY992D88201

Describes contents related to hardware of FX

1N

 Series PLC such 

as specifications, wiring and installation.

FX

 

Programming 

Manual 

II

JY992D88101

Describes instructions in FX

1S

/FX

1N

/FX

2N

/FX

2NC

 Series.

FX Series User's 
Manual - Data 
Communication 
Edition

JY997D16901

Describes contents related to communication available in FX 
Series PLC such as wiring, communication setting and program 
examples. (Make sure to read this manual.)

1.2 Outside dimensions and name of each part

1.3 System configuration

For the system configuration, refer to the FX Series User's Manual - Data Communication Edition offered
separately.

2. Installation

2.1 Installation procedure

Make sure to turn off the power before installing the 485BD.

A)

Communication board 485BD (function expansion board)

B)

Connector for optional equipment

C)

M3 screw to fix board (2 pieces) (offered as accessories of board)

D)

Top cover for board (offered as an accessory of board)

E)

M3 screw to fix top cover (offered as an accessory of board)

Note: Do not remove this screw of FX

1S

.

Plug the communication board 

A)

 in to the connector 

B)

.

Fix the board to the basic unit with two M3 screws 

C)

. (Tightening 

torque: 0.3 to 0.6 N

x

m)

Remove the top cover of the basic unit, and attach the top cover for 
board 

D)

 instead.

During attachment, remove 

D)’

 with a nipper, etc. so that the connector of the board is exposed.

Fix the top cover with the M3 screw 

E)

. (Tightening torque: 0.3 to 0.6 N

x

m)

When the FX

1N

-5DM is used also, refer to the Hardware manual offered with the FX

1S

/FX

1N

 Series 

PLC main unit.

Only one function expansion board is available for one FX

1S

/FX

1N

 Series PLC basic unit. Never stack 

up two or more function expansion boards. (Even if they are stacked up, they do not function at all.)

The 485BD can be used with the FX

1N

-EEPROM-8L only for program transfer.

(The FX

1N

-EEPROM-8L cannnot be connected continuously.)

SD
B

RDA

S

D

A

RDB

S

G

38.5

 (1.

52)

43 (1.69)

SD

RD

Unit: mm (inches)

Accessories: Top cover for board   1

Terminal resistor 330

   2

Terminal resistor 110

   1

M3 screw to mount board   2
M3 screw to fix top cover   1
Station No. label for link

Mounting hole (2-

φ

3.5)

Connector for PLC 

Terminal block for RS-485 equipment
The top face of this terminal box is higher than the top face of the
PLC panel cover by approximately 7 mm.

SD LED: Flickers at high speed during send.

RD LED: Flickers at high speed during receive.

Connector for display module FX

1N

-5DM or memory cassette

FX

1N

-EEPROM-8L

A)

B

)

C)

D

)

D

)'

E)

C)

Note)

3. Specifications

3.1 Environmental specifications

The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of the
PLC main unit.)

3.2 Power supply specifications

5V DC, 60 mA is supplied as the power from the PLC.

3.3 Performance specifications

Transmission standard

In conformance to RS-485 and RS-422

Maximum transmission 
distance

50m (164ft) maximum

Communication type

No protocol communication, Computer link (dedicated protocol), 
parallel link, N:N network 

Communication method

Half duplex, bi-directional 

Communication 
procedure

No protocol communication, Computer link (dedicated protocol 1, 
dedicated protocol 4), parallel link, N:N network 

Transmission speed
(baud rate)

No protocol communication, Computer link (dedicated protocol): 300 to 
19200 bps
Parallel link:   19200(bps)
N:N network:  38400(bps)

Insulation

None

Guidelines for the safety of the user and protection of the RS-485 
Communication Board FX

1N

-485-BD

This manual has been written to be used by trained and competent personnel. This is defined
by the European directives for machinery, low voltage and EMC.

If in doubt at any stage during the installation of the RS-485 Communication Board FX

1N

-485-

BD always consult a professional electrical engineer who is qualified and trained to the local
and national standards. If in doubt about the operation or use of the RS-485 Communication
Board FX

1N

-485-BD please consult the nearest Mitsubishi Electric distributor. 

Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential
damage that may arise as a result of the installation or use of this equipment. 

All examples and diagrams shown in this manual are intended only as an aid to understanding
the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual
use of the product based on these illustrative examples. 

Owing to the very great variety in possible application of this equipment, you must satisfy
yourself as to its suitability for your specific application. 

Manual number : JY992D84201

Manual revision : C

Date

: AUGUST 2006

JY992D84201C

Effective Aug. 2006

Specifications are subject to 
change without notice

Reviews: