background image

i

FX-10GM POSITIONING CONTROLLER

FX-10GM POSITIONING CONTROLLER
USER'S GUIDE

Manual number:

JY992D68401

Manual revision:

A

Date:

September   1997

Foreword

• This manual only describes the specifications for FX-10GM positioning controller.

For complete operation, wiring, mounting and programming instructions please refer
to the FX-10GM, FX(E)-20GM HARDWARE/PROGRAMMING MANUAL, FX
PROGRAMMING MANUAL and FX SERIES HARDWARE MANUAL.

• Before attempting to install or use the FX-10GM unit this manual and FX-

10GM,FX(E)-20GM HARDWARE/PROGRAMMING MANUAL should be read and
understood.

• If in doubt at any stage of the installation of the FX-10GM unit always consult

a professional electrical engineer who is qualified and trained to  the local and
national standards which apply to the installation site.

• If in doubt about the operation or use of the FX-10GM unit please consult the nearest

Mitsubisi Electric distributor.

• This manual is subject to change without notice.

Summary of Contents for FX-10GM

Page 1: ...RAMMING MANUAL and FX SERIES HARDWARE MANUAL Before attempting to install or use the FX 10GM unit this manual and FX 10GM FX E 20GM HARDWARE PROGRAMMING MANUAL should be read and understood If in doub...

Page 2: ...FX 10GM POSITIONING CONTROLLER ii...

Page 3: ...e completed equipment should be trained to use that product in a safe and co ordinated manner in compliance to established safety practices The operators should also be familiar with documentation whi...

Page 4: ...iguration 1 3 1 3 External Dimensions 1 4 2 SPECIFICATIONS 2 1 2 1 General Specifications 2 1 2 2 Power Supply Specifications 2 1 2 2 1 Power Supply Specifications 2 1 2 2 2 Service power supply 2 2 2...

Page 5: ...o motor via the drive unit Number of control axes Positioning languages Number of output pulses Connection to Programmable controller 1 Dedicated language Sequence language 1 to 200 kPPS Connected to...

Page 6: ...nit block for the programmable controller Mounting hole 2 5 5 DIN rail Not used when the unit is mounted to a DIN rail Operation indicator LEDs I O output status indicator LEDs 2C MANU COM1 1 2 System...

Page 7: ...Y7 COM3 Y11 Y13 COM4 Y15 Y17 PULL 24 24 COM1 MANU B POWER 3 7 0 4 1 5 2 6 3 7 0 4 1 5 2 6 A POWER 3 7 0 4 1 5 2 6 3 7 0 4 1 5 2 6 TRANSISTOR BLOCK A B 24 24 COM1 MANU 1 0 1 2 3 COM COM 4 5 6 7 COM COM...

Page 8: ...5 6 Various data settings can be fetched through connections that save wiring either by a direct connection method or by multiplexing input outputs General output extension output 1 Auxiliary equipme...

Page 9: ...d Stop command Zero return command 2 Mechanical system inputs Forward rotation limit Reverse rotation limit Near point dog signal Manual forward rotation command Manual reverse rotation command Manual...

Page 10: ...ZRN STOP Y5 X0 X1 X2 X3 Y0 Y1 Y2 Y3 Y4 CLR MANU SVRDY SVEND PGO FP RP CPU E POWER READY ERROR 140 125 Width 35mm DIN rail moun ting groove 10 40 50 95 2 5 5 Mounting hole 1 3 External Dimensions Weig...

Page 11: ...not allowed 2 Ambient atmosphere Free from corrosive gas and excessive dust 1 0 5G when mounted to a DIN rail 2 2 SPECIFICATIONS For complefe operation wiring mounting and programming instructions ple...

Page 12: ...ormance Specifications Item Specifications Number of control axes 1 Applicable programmable controller Bus connection with FX FX2C Series PC Number of I O points occuupied 8 points Program memory 3 8k...

Page 13: ...with instruction cods 13 types Sequence 11 types LD LDI AND ANI OR ORI ANB ORB SET RST NOP Application FNC No system 29 types M codes maintask m00 WAIT program stop and m02 END m01 m03 to m99 can be...

Page 14: ...r less 0 3 mA or less PG0 0 5 mA or less Signal format Contact input or NPN open collector transistor input Response time Group 1 Approx 0 5 msec Approx 3 msec Group 2 Approx 3 msec Approx 3 sec Group...

Page 15: ...utput is ON LED is lit while output is ON External power supply 5 to 24V DC 10 5 to 24V DC 10 Load current 20 mA or less 50 mA or less Open circuit leak current 0 1 mA 24V DC or less 0 1 mA 24V DC or...

Page 16: ...connector cables made by the user and for the connectors to be used when connecting additional equipment are indicated below 1 When making a cable Flat cables Wire size AWG28 0 1 mm2 1 27 pitch 20 co...