7.7 Changing the Inverter Network No. and Station No.
Apply the settings below in order to change the inverter network number and station number.
Switches in B-14000 [Station Number Switching] Screen
(1) Open the [Station No. Switching] under [Action List] and change the network number and station number.
(2) Change the [Constant] of the [Lamp] function to the same network number and station number that have been
changed in (1)*1.
Enter the new network
number and station number.
*1 The structure of the value stored in the station number switching device is as
below.
Set the constant in hexadecimal format.
•
Upper 8 bits: Network No.
•
Lower 8 bits: Station No.
■Ethernet and CC-Link IE TSN
Example 1: Network No.1 and Station No.25
01 19
Station No.
Network No.
■RS-485 connection
Example 2: Network No.0 and Station No.0
00 00
Station No.
Network No. is "0" (fixed).
Enter the constant
according to the new
network number and station
number