OPEN
NV800-SEW, NV800-HEW
NF1000-SEW, NF1250-SEW, NF1600-SEW
TYPE
NV250-SEW, NV250-HEW
NF400-SEW, NF400-HEW, NF400-REW, NF400-UEW
NV400-SEW, NV400-HEW, NV400-REW
NF630-SEW, NF630-HEW, NF630-REW, NV630-SEW, NV630-HEW
NF800-CEW, NF800-SEW, NF800-HEW, NF800-REW
NF800-UEW, NV800-SEW, NV800-HEW
NF1000-SEW, NF1250-SEW, NF1600-SEW
NO CURRENT
Reset condition
of indicator
Discharge the electrostatic charge
from the operator's body before
test. Otherwise,the indicator of
Y-250 may be reset.
2
1
INSTRUCTIONS MANUAL
BREAKER TESTER Y-250
ON
OFF
BREAKER
ON
POWER switch ON
UP/DOWN SWITCH
MODE SWITCH
push UP switch
push
push
push
push
push
push DOWN switch
push DOWN switch
push UP switch
95
×
158
×
48mm
0
℃〜
40
℃
Battery type R6P
(
1.5V
×
6
)
0.00
〜
0.99s
±
0.01s
1.00
〜
999s
±
1%
LTD, PAL pickup and operating time
Operating time
Setting point of characteristics
30%
〜
300% of the maximum rated current
STD 1500% of the maximum rated current
INST 2000% of the maximum rated current
CHECK
Specification
CURRENT
(
LTD or PAL mode
)
Test items
Power source
Ambient temperature for use
Outer dimensions
The range of measuring time
NV250-SEW, NV250-HEW
NF125-SGW
(
RE
)
, NF125-HGW
(
RE
)
NF160-SGW
(
RE
)
, NF160-HGW
(
RE
)
NF250-SGW
(
RE
)
, NF250-HGW
(
RE
)
NF400-SEW, NF400-HEW, NF400-REW, NF400-UEW
NV400-SEW, NV400-HEW, NV400-REW
NF630-SEW, NF630-HEW, NF630-REW, NV630-SEW, NV630-HEW
NF800-CEW, NF800-SEW, NF800-HEW, NF800-REW, NF800-UEW
TYPES
TYPE
NF125-SGW
(
RE
)
, NF125-HGW
(
RE
)
NF160-SGW
(
RE
)
, NF160-HGW
(
RE
)
NF250-SGW
(
RE
)
, NF250-HGW
(
RE
)
The connector can be inserted only
in the prescribed direction.
5
〜
7
T =12
L
10
〜
14
L
T =12
100
63
10
5.1
NV250-SEW/HEW
NF125-SGW
(
RE
)
NF125-HGW
(
RE
)
NF160-SGW/HGW
(
RE
)
NF250-SGW/HGW
(
RE
)
250
32
63
100
125
160
250
NF400-SEW/HEW
NF400-REW/UEW
NV400-SEW/HEW
NV400-REW
400
NF630-SEW/HEW
NF630-REW
NV630-SEW/HEW
NF800-CEW/SEW
NF800-HEW/REW
NV800-SEW/HEW
NF800-UEW
NF1000-SEW
NF1250-SEW
NF1600-SEW
630
800
1000
1250
1600
16
53
〜
62
50
30
〜
40
100
32
100
105
〜
125
60
〜
80
200
32
51
53
〜
63
30
〜
40
102
100
105
〜
125
60
〜
80
200
63
63
65
〜
80
40
〜
50
126
63
100
105
〜
125
60
〜
80
200
100
125
60
63
〜
75
36
〜
48
120
A number of flashing and characteristics setting point
75
100
105
〜
125
60
〜
80
200
160
50
53
〜
62
30
〜
40
100
80
100
105
〜
125
60
〜
80
200
250
50
53
〜
62
30
〜
40
100
125
100
105
〜
125
60
〜
80
200
*1
I
r
(
A
)
10
125
6
10
160
5
Replace battelies
10
6.3
Note *1: In case of type NF125/160/250-SGW/HGW
(
RE
)
.
Even if it makes Ts into which value
(
0.06-0.1-0.2-0.3
)
in the test of
STD pick up
(
mode-S
)
, the test result is displayed as "0.06".
However, it is not the abnormalities of the breaker tester.
In practice, it is set up as setting value.
Only when tested by "Y-250".
INST
0.00
〜
0.02
T =0.06
S
S
S
S
T =0.1
T =0.2
T =0.3
0.02
〜
0.06
0.05
〜
0.11
0.14
〜
0.22
0.22
〜
0.34
L
L
L
L
L
L
L
L
T =60
T =100
T =150
T =12
5
〜
7
24
〜
36
40
〜
60
60
〜
90
T =12
T =60
T =100
T =150
10
〜
14
48
〜
72
80
〜
120
120
〜
180
24
〜
36
32
〜
48
40
〜
60
L
L
L
T =60
T =80
T =100
T =100
L
80
〜
120
T =80
L
64
〜
96
T =60
L
48
〜
72
(
s
)
(
s
)
(
s
)
I
T
(
A
)
(
%I
T
)
(
%I
T
)
(
%I
T
)
(
%I
T
)
(
A
)
Ir
STD and INST
operating time
PAL operating
time
Operating
time
Signal
level
Operating time at 200%
70% PAL pick
up current
LTD pick up
current
Current setting
Reference
current of
test
Type
1600
100
105
〜
125
60
〜
80
200
94
1500
98
〜
117
56
〜
75
188
88
1400
92
〜
109
53
〜
70
175
150
45
〜
60
79
〜
93
75
1200
127
40
〜
50
65
〜
80
63
1000
100
30
〜
40
53
〜
62
50
800
105
〜
125
100
1250
60
〜
80
200
1200
96
101
〜
120
58
〜
77
192
1000
80
84
〜
100
48
〜
64
160
800
64
67
〜
80
38
〜
51
128
700
56
60
〜
70
34
〜
45
112
600
48
50
〜
60
29
〜
38
96
1000
100
105
〜
125
60
〜
80
200
900
90
95
〜
112
54
〜
72
180
800
80
84
〜
100
48
〜
64
160
700
70
74
〜
87
42
〜
56
140
600
60
63
〜
75
36
〜
48
120
500
50
53
〜
62
30
〜
40
100
800
100
105
〜
125
60
〜
80
200
700
87
92
〜
109
52
〜
70
175
600
75
79
〜
93
45
〜
60
150
500
62
66
〜
78
37
〜
50
125
450
56
60
〜
70
34
〜
45
112
400
50
53
〜
62
30
〜
40
100
630
100
105
〜
125
60
〜
80
200
600
95
98
〜
120
60
〜
74
190
500
79
81
〜
100
50
〜
62
159
400
63
65
〜
80
40
〜
50
127
350
55
57
〜
70
35
〜
44
111
300
47
48
〜
60
30
〜
38
95
400
100
105
〜
125
60
〜
80
200
350
87
92
〜
109
52
〜
70
175
300
75
79
〜
93
45
〜
60
150
250
62
66
〜
78
37
〜
50
125
225
56
60
〜
70
34
〜
45
112
200
50
53
〜
62
30
〜
40
100
225
90
95
〜
112
54
〜
72
180
200
80
84
〜
100
48
〜
64
160
175
70
74
〜
87
42
〜
56
140
150
60
63
〜
75
36
〜
48
120
125
50
53
〜
62
30
〜
40
100
I
P
(
×
Ir
)
0.95
0.85
0.75
1.0
0.9
0.8
0.7
T
S
(
S
)
0.3
0.2
0.1
0.06
I
S
(
×
Ir
)
3.5
2.5
10
8
7
6
5
4
3
2
For 400, 630, 800, 1000, 1250 and 1600A Frame
100
150
60
12
For 125, 160 and 250A Frame
100
80
60
12
T
L
(
S
)
Lighting-up time of 70% LED
(
s
)
Time
Max. adjust
Min. adjust
Ref. Current
(
A
)
9
5
5
5
5
5
5
10
10
10
10
10
800
630
400
250
225
32
1000
5
10
5
10
5
10
1250 1600
Number
8
7
6
5
4
3
2
1
10
9
Reference for
test
0.4 N
・
m
BATTERY TYPE
:
R6P
(
1.5V
×
6
)
IB63819-E 1512
(
MEE
)