12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
533
12
[Cd.136] PI-PID switching request
• Set the PI-PID switching to servo amplifier.
Fetch cycle: Operation cycle
■
Setting value
• Set with a decimal
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Cd.138] Control mode switching request
• Request the control mode switching. Set "1" after setting "[Cd.139] Control mode setting".
• The Simple Motion module sets "0" at completion of control mode switching.
Fetch cycle: Operation cycle
■
Setting value
• Set with a decimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Cd.139] Control mode setting
• Set the control mode to be changed in the speed-torque control.
Fetch cycle: At control mode switching
■
Setting value
• Set with a decimal.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
PI-PID switching request
1 : PID control switching request
Other than 1: Not request
Setting
value
K
Setting
value
Control mode switching request
1 : Switching request
Other than 1: Not request
K
Setting
value
K
Control mode setting
0: Position control mode
10: Speed control mode
20: Torque control mode
30: Continuous operation to torque control mode
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......