![Mitsubishi Electric RD77MS16 User Manual Download Page 469](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857469.webp)
12 DATA USED FOR POSITIONING CONTROL
12.6 Condition Data
467
12
[Da.19] Parameter 2
Set the parameters as required for the "[Da.16] Condition operator" and "[Da.23] Number of simultaneously starting axes".
[Da.23] Number of simultaneously starting axes
Set the number of simultaneously starting axes to execute the simultaneous start.
[Da.24] Simultaneously starting axis No.1 to [Da.26] Simultaneously starting axis No.3
Set the simultaneously starting axis to execute the 2 to 4-axis simultaneous start.
Set the axis set as simultaneously starting axis.
*1
Do not specify the own axis number or the value outside the range. Otherwise, the error "Condition data error" (error code: 1A00H to
1A05H) will occur during the program execution.
*2
When the same axis number or axis number of own axis is set to multiple simultaneously starting axis number, the error "Condition data
error" (error code: 1A00H to 1A05H) will occur during the program execution.
*3
Do not specify the simultaneously starting axis No.2 and simultaneously starting axis No.3 for 2-axis simultaneously start, and not
specify the simultaneously starting axis No.3 for 3-axis simultaneously start. The setting value is ignored.
[Da.16] Condition
operator
[Da.23] Number of
simultaneously
starting axes
Setting value
Setting details
01H: ** = P1
Not used. (No need to be set.)
02H: **
P1
03H: **
P1
04H: **
P1
05H: P1
**
P2
Value
The value of P2 should be equal to or greater than the value of P1. (P1
P2)
If P1 is greater than P2 (P1 > P2), the error "Condition data error" (error code:
1A00H to 1A05H) will occur.
06H: **
P1, P2
**
07H: DEV = ON
Not used. (No need to be set.)
08H: DEV = OFF
2 to 3
4
Value
(positioning data No.)
Set the positioning data No. for starting axis set in "[Da.26] Simultaneously
starting axis No.3"
Low-order 16-bit: Simultaneously starting axis No.3 positioning data No. 1 to
600 (01H to 258H)
High-order 16-bit: Not used (Set "0")
Number of axes
Details
2
Simultaneous start by 2 axes of the starting axis and axis set in "[Da.24] Simultaneously starting axis No.1".
3
Simultaneous start by 3 axes of the starting axis and axis set in "[Da.24] Simultaneously starting axis No.1" and "[Da.25] Simultaneously
starting axis No.2".
4
Simultaneous start by 4 axes of the starting axis and axis set in "[Da.24] Simultaneously starting axis No.1" to "[Da.26] Simultaneously
starting axis No.3".
Simultaneously
starting axis
Details
2-axis interpolation
Set the target axis number in "[Da.24] Simultaneously starting axis No.1".
3-axis interpolation
Set the target axis number in "[Da.24] Simultaneously starting axis No.1" and "[Da.25] Simultaneously starting axis No.2".
4-axis interpolation
Set the target axis number in "[Da.24] Simultaneously starting axis No.1" to "[Da.26] Simultaneously starting axis No.3".
0: Axis
1
8: Axis
9
1: Axis
2
9: Axis
10
2: Axis 3
A: Axis 11
3: Axis 4
B: Axis 12
4: Axis 5
C: Axis 13
5: Axis 6
D: Axis 14
6: Axis 7
E: Axis 15
7: Axis 8
F: Axis 16
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......