![Mitsubishi Electric RD77MS16 User Manual Download Page 296](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857296.webp)
294
8 CONTROL SUB FUNCTIONS
8.9 Other Functions
Deceleration start flag function
The "deceleration start flag function" turns ON the flag when the constant speed status or acceleration status switches to the
deceleration status during position control whose operation pattern is "Positioning complete". This function can be used as a
signal to start the operation to be performed by other equipment at each end of position control or to perform preparatory
operation, etc. for the next position control.
Control details
When deceleration for a stop is started in the position control whose operation pattern is "Positioning complete", "1" is stored
into "[Md.48] Deceleration start flag". When the next operation start is made or the manual pulse generator operation enable
status is gained, "0" is stored. (Reference to the figure below)
■
Start made with positioning data No. specified
■
Block start
At a block start, this function is valid for only the position control whose operation pattern is "Positioning complete" at the point
whose shape has been set to "End". (Reference to the figure below)
The following table indicates the operation of the deceleration start flag in the case of the following block start data and
positioning data.
Block start data
[Da.11] Shape
[Da.12] Start data No.
[Da.13] Special start
instruction
1st point
1: Continue
1
0: Block start
2nd point
1: Continue
3
0: Block start
3rd point
0: End
4
0: Block start
Positioning Data No.
[Da.1] Operation pattern
1
01: Continuous positioning control
2
00: Positioning complete
3
00: Positioning complete
4
11: Continuous path control
5
00: Positioning complete
t
Operation pattern: Positioning complete (00)
V
[Md.48] Deceleration start flag 0
1
0
t
1st point: Continue (1)
3rd point: End (0)
2nd point: Continue (1)
Operation
pattern
Continuous path
control (11)
Positioning
data No. 4
Positioning
data No. 5
Positioning complete (00)
Continuous
positioning
control (01)
Positioning
data No. 1
Positioning
data No. 2
Positioning complete (00)
Positioning
data No. 3
Positioning complete (00)
V
[Md.48] Deceleration start flag 0
1
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......