10.10
Z.RECVS (Receiving Data from the Programmable
Controller on Another Station)
This instruction reads the data received from the programmable controller on another station. (For interrupt programs)
*1
Local devices and file registers set for each program cannot be used.
(1) Setting data
Setting
data*
1
Available devices
Internal device
(System, user)
File
register
R, ZR
Link direct device
J
\
Intelligent
function module
device
U
\G
Index
register
Zn
Constant
Others
Bit
Word
Bit
Word
K, H
$
(S1)
(D1)
(D2)
Setting data
Description
Set by
Data type
"Un"/Un
Start I/O number of the master/local module of the own station
(00 to FE
H
: Upper two digits of the I/O number expressed in three
digits)
User
String/
16-bit binary
(S1)
Start device of the own station where control data is stored
Device name
(D1)
Start device of own station where received data is stored
(A continuous area for the received data length is required.)
System
(D2)
Dummy
Bit
Z.RECVS
Start contact
Z.RECVS
Un
or
"
"
Un
(S1)
(D1)
(D2)