![Mitsubishi Electric Q06CCPU-V User Manual Download Page 266](http://html.mh-extra.com/html/mitsubishi-electric/q06ccpu-v/q06ccpu-v_user-manual_1811831266.webp)
6
- 48
6.7 Specifications, Installation, and Replacement of the Battery
6.7.2 Battery installation
6
PREPARATORY PROCEDURES AND SETTING
6.7.2
Battery installation
The battery connector is disconnected from the battery before shipping.
Connect the battery connector before use.
POINT
Firmly push the battery connector all the way in to the connector pin.
Figure 6.42 Battery installation
IMPORTANT
A battery must be installed for operation.
When the Q12DCCPU-V is operated without installing a battery and then the C Controller
system is powered off or reset, the standard RAM or battery-backed-up RAM data may
be damaged, or a file system error may occur.
If the Q06CCPU-V(-B) is operated without battery, set clock data and perform proper
shutdown operation. (
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B
End
Connect the battery connector to
the connector pin on the case,
checking the orientation.
Open the C Controller module
bottom cover.
Check the battery is correctly
installed.
C Controller module
Place the excess lead wire on the top of the battery
as shown below.
Connector
Connector stopper
Lead wire
of the battery
Battery