![Mitsubishi Electric Q06CCPU-V User Manual Download Page 133](http://html.mh-extra.com/html/mitsubishi-electric/q06ccpu-v/q06ccpu-v_user-manual_1811831133.webp)
4
FUNCTIONS
4.8 Input Response Time Selection (I/O Response Time)
4
- 34
1
O
V
ER
VI
E
W
2
SY
STEM
CONFIGURA
TION
3
SP
ECIFICA
T
IONS
4
FUNCTIONS
5
A
C
C
E
SS V
IA
N
E
TW
OR
K
MODUL
ES
6
P
R
EP
AR
A
T
OR
Y
PROCE
DUR
ES
A
ND
S
E
TTING
7
I/O NUM
BER
ASS
IGN
M
EN
T
8
M
E
M
O
RIE
S
A
ND
FI
L
E
S
4.8
Input Response Time Selection (I/O Response Time)
(1) What is the input response time selection?
The input response time can be changed for each Q series module.
The following table shows the modules whose input response time can be changed
and time options for them.
The above Q series modules load external inputs within the specified input response
time.
Table 4.9 Modules whose input response time can be changed
Module whose input response time
can be changed
Type
Option
Input module
Input
1ms, 5ms, 10ms, 20ms, 70ms
(Default: 10ms)
I/O combined module
I/O Mix
High-speed input module
Hi Input
0.1ms, 0.2ms, 0.4ms, 0.6ms, 1ms
(Default: 0.2ms)
Interrupt module
Interrupt
Figure 4.11 Input response time
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B
OFF
OFF
ON
ON
Input response time
Q series module
External input
Summary of Contents for Q06CCPU-V
Page 2: ......
Page 612: ...APPX 48 Appendix 11 Functions Added by Version Upgrade APPENDICES Memo ...
Page 617: ......