1. Safety precautions

►  Before  installing  the  unit,  make  sure  you  read  all  the  “Safety  precau

-

tions”.

►  Please report to or take consent by the supply authority before connec

-

tion to the system.

►  Equipment complying with IEC/EN 61000-3-12

  (PUZ-HWM140VHA)

After installation work has been completed, explain the “Safety Precautions,” use, 

and maintenance of the unit to the customer according to the information in the 

Operation Manual and perform the test run to ensure normal operation. Both the 

Installation Manual and Operation Manual must be given to the user for keeping. 

These manuals must be passed on to subsequent users.

 : Indicates a part which must be grounded.

 Warning:

Carefully read the labels affixed to the main unit.

 Warning:

•   The unit must not be installed by the user. Ask a dealer or an authorized 

technician to install the unit. If the unit is installed incorrectly, water leak

-

age, electric shock, or fire may result.

•    For installation work, follow the instructions in the Installation Manual and 

use tools and pipe components specifically made for use with R32 refriger

-

ant. The R32 refrigerant in the HFC system is pressurized 1.6 times the pres

-

sure of usual refrigerants. If pipe components not designed for R32 refriger

-

ant are used and the unit is not installed correctly, the pipes may burst and 

cause damage or injuries. In addition, water leakage, electric shock, or fire 

may result.

•   When installing the unit, use appropriate protective equipment and tools for 

safety.

  Failure to do so could cause injuries.

•   The unit must be installed according to the instructions in order to mini

-

mize the risk of damage from earthquakes, typhoons, or strong winds. An 

incorrectly installed unit may fall down and cause damage or injuries.

•    The unit must be securely installed on a structure that can sustain its 

weight. If the unit is mounted on an unstable structure, it may fall down 

and cause damage or injuries.

•   If the outdoor unit is installed in a small room, measures must be taken to 

prevent the refrigerant concentration in the room from exceeding the safe

-

ty limit in the event of refrigerant leakage. Consult a dealer regarding the 

appropriate measures to prevent the allowable concentration from being 

exceeded. Should the refrigerant leak and cause the concentration limit to 

be exceeded, hazards due to lack of oxygen in the room may result.

•   Ventilate the room if refrigerant leaks during operation. If refrigerant 

comes into contact with a flame, poisonous gases will be released.

•   All electric work must be performed by a qualified technician according to 

local regulations and the instructions given in this manual. The units must 

be powered by dedicated power lines and the correct voltage and circuit 

breakers must be used. Power lines with insufficient capacity or incorrect 

electrical work may result in electric shock or fire.

•   This appliance is intended to be used by expert or trained users in shops, 

in light industry and on farms, or for commercial use by lay persons.

•   Use only specified cables for wiring. The wiring connections must be 

made securely with no tension applied on the terminal connections. Also, 

never splice the cables for wiring (unless otherwise indicated in this docu

-

ment).

   Failure to observe these instructions may result in overheating or a fire.

•    If the supply cord is damaged, it must be replaced by the manufacturer, its 

service agent or similarly qualified persons in order to avoid hazard.

•   The appliance shall be installed in accordance with national wiring regula

-

tions.

•   The terminal block cover panel of the outdoor unit must be firmly attached. 

If the cover panel is mounted incorrectly and dust and moisture enter the 

unit, electric shock or fire may result.

•   When installing or relocating, or servicing the outdoor unit, use only the 

specified refrigerant (R32) to charge the refrigerant lines. Do not mix it 

with any other refrigerant and do not allow air to remain in the lines.

  If air is mixed with the refrigerant, then it can be the cause of abnormal 

high pressure in the refrigerant line, and may result in an explosion and 

other hazards.

 

The use of any refrigerant other than that specified for the system will cause 

mechanical failure or system malfunction or unit breakdown. In the worst 

case, this could lead to a serious impediment to securing product safety.

•   Use only authorized accessories and ask a dealer or an authorized techni

-

cian to install them. If accessories are incorrectly installed, water leakage, 

electric shock, or fire may result.

•   Do not alter the unit. Consult a dealer for repairs. If alterations or repairs 

are not performed correctly, water leakage, electric shock, or fire may 

result.

•   The user should never attempt to repair the unit or transfer it to another 

location. If the unit is installed incorrectly, water leakage, electric shock, or 

fire may result. If the outdoor unit must be repaired or moved, ask a dealer 

or an authorized technician.

 Warning:

Describes precautions that must be observed to prevent danger of injury or 

death to the user.

 Caution:

Describes precautions that must be observed to prevent damage to the unit.

Note: This symbol mark is for EU countries only.

This symbol mark is according to the directive 2012/19/EU Article 14 Information for users and Annex IX.

Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused.

This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.

Please, dispose of this equipment at your local community waste collection/recycling centre.

In the European Union there are separate collection systems for used electrical and electronic product.

Please, help us to conserve the environment we live in!

 Caution:

• Do not vent R32 into the Atmosphere:

1. Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

2. Installation location  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3. Installing the outdoor unit   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4. Water piping work  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5. Electrical work  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

6. System control   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

7. Specifications

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

8. Serial number   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

MEANINGS OF SYMBOLS DISPLAYED ON THE UNIT

WARNING

(Risk of fire)

This mark is for R32 refrigerant only. Refrigerant type is written on nameplate of outdoor unit.

In case that refrigerant type is R32, this unit uses a flammable refrigerant.

If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.

Read the OPERATION MANUAL carefully before operation.

Service personnel are required to carefully read the OPERATION MANUAL and INSTALLATION MANUAL before operation.

Further information is available in the OPERATION MANUAL, INSTALLATION MANUAL, and the like.

Contents

RH79D007H02_01en.indd   1

2020/09/25   17:18:51

003

Summary of Contents for PUZ-HWM140HA Series

Page 1: ...ngielskim Pozostałe wersje językowe zostały przetłumaczone z oryginału INSTALLASJONSHÅNDBOK FOR MONTØR For å sikre trygg og riktig bruk skal denne håndboken samt installasjonshåndboken for innendørsenheten leses grundig igjennom før enheten installeres Engelsk er originalspråket De andre språkversjonene er oversettelser av originalen ASENNUSOPAS ASENTAJALLE Turvallisen ja asianmukaisen käytön varm...

Page 2: ...а потім мову bg Посетете горепосочения уебсайт за да изтеглите ръководства като изберете име на модел и след това език pl Odwiedź powyższą stronę internetową aby pobrać instrukcje wybierz nazwę modelu a następnie język cs Příručky naleznete ke stažení na internetové stránce zmíněné výše poté co zvolíte model a jazyk sk Na webovej stránke vyššie si môžete stiahnuť návody Vyberte názov modelu a zvoľ...

Page 3: ...tions may result in overheating or a fire If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid hazard The appliance shall be installed in accordance with national wiring regula tions The terminal block cover panel of the outdoor unit must be firmly attached If the cover panel is mounted incorrectly and dust and moi...

Page 4: ... etc 1 2 Before installation relocation Caution Be extremely careful when transporting or installing the units Two or more persons are needed to handle the unit as it weighs 20 kg or more Do not grasp the packaging bands Wear protective gloves to remove the unit from the packaging and to move it as you can injure your hands on the fins or the edge of other parts Be sure to safely dispose of the pa...

Page 5: ...snow fall is anticipated special precautions such as raising the installation loca tion or installing a hood on the air intake must be taken to prevent the snow from blocking the air intake or blowing directly against it This can reduce the airflow and a malfunction may result Avoid locations exposed to oil steam or sulfuric gas Use the transportation handles of the outdoor unit to transport the u...

Page 6: ...irflow and a malfunction may result The following shows three examples of precautions against strong winds 1 Face the air outlet towards the nearest available wall about 35 cm away from the wall Fig 2 3 2 Install an optional air protect guide if the unit is installed in a location where strong winds from a typhoon etc may directly enter the air outlet Fig 2 4 A Air protect guide 3 Position the uni...

Page 7: ...uide installed for upward airflow the clearance is 1000 mm or more 7 Stacked unit arrangement Fig 2 18 The units can be stacked up to two units high No more than 2 stacked units must be installed side by side In addition leave space as shown 2 Installation location UNIT mm Fig 2 6 Fig 2 7 Fig 2 8 Fig 2 9 Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 13 Fig 2 14 Fig 2 15 Fig 2 16 Fig 2 17 Fig 2 18 2 3 2 When in...

Page 8: ...nt C Create an appropriate ventilation open area Make sure that the width of the open area is 0 9 m or more and the height of the open area is 0 15 m or more However the height from the bottom of the installation space to the bottom edge of the open area should be 0 125 m or less Open area should be 75 or more opening B Install in a space with a depression height of 0 125 m Amin Height from the bo...

Page 9: ...unit Do not block the vent If the vent is blocked operation will be hindered and break down may result In addition to the unit base use the installation holes on the back of the unit to attach wires etc if necessary to install the unit Use self tapping screws ø5 15 mm or less and install on site Warning The unit must be securely installed on a structure that can sustain its weight If the unit is m...

Page 10: ...wable range the parts of unit might be damaged Fig 4 2 Parts Check every Possible failures Pressure relief valve 3 bar 1 year pushing the lever manu ally PRV would be fixed and expansion vessel would burst Lever Water outlet Caution Operate the lever when the water temperature falls below 40 C Check that the water outlet of the pressure relief valve is facing downward before operating the lever If...

Page 11: ...he water quantity of system Minimum return water temperature due to the water quantity of system Note Be sure to avoid the unavailable range during defrosting Otherwise the outdoor unit is insufficiently defrosted and or the heat exchanger of the indoor unit may freeze 4 5 Available range Water flow rate return water temp Cooling 15 L 25 L 25 L 40 L 40 L 60 L over 60 L Available range Available ra...

Page 12: ...lock G Indoor Outdoor connection terminal block S1 S2 S3 H Service panel J Earth terminal K Clamp Clamp the cables so that they do not contact the center of the service panel Note If the protective sheet for the electrical box is removed during servicing be sure to reinstall it Caution Be sure to install N Line Without N Line it could cause damage to unit Single phase Three phase For Power L N S1 ...

Page 13: ...ply cord if any shall be blue Outdoor Unit 3 poles isolator Isolator Indoor Unit Flow temp controller Warning In case of A control wiring there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power line and communication signal line Therefore please turn off the main power supply when servicing And do not touch the S1 S2 S3...

Page 14: ...N OFF 3 4 5 6 7 01 ON OFF 3 4 5 6 7 04 ON OFF 3 4 5 6 7 02 ON OFF 3 4 5 6 7 05 7 Specifications 8 Serial number Outdoor model PUZ HWM140VHA PUZ HWM140YHA Power supply V Phase Hz 230 Single 50 400 Three 50 Dimensions W H D mm 1020 1350 330 Sound Power Level 1 Heating dB A 67 1 Measured under rated operation frequency U Sequential number for each unit 00001 99999 Month of manufacture 4 5 6 7 8 9 X 1...

Page 15: ... commerciële en licht industriële omgevingen bestemde airconditioners en warmtepompen zoals onderstaand beschreven por la presente declara bajo su única responsabilidad que los acondicionadores de aire y bombas de calor descritas a continuación para su uso en entornos residenciales comerciales y de industria ligera conferma con la presente sotto la sua esclusiva responsabilità che i condizionatori...

Page 16: ...leken ESPAÑOL El idioma original del documento es el inglés Las versiones en los demás idiomas son traducciones del original CUIDADO Las pérdidas de refrigerante pueden causar asfixia Se debe proporcionar la ventilación de terminada en EN378 1 Asegúrese de colocar el aislante alrededor de las tuberías El contacto directo con la tubería puede ocasionar quemaduras o congelación Para evitar una inges...

Page 17: ...Contactul direct cu conductele neizo late se poate solda cu arsuri sau degerături Nu introduceţi niciodată şi pentru niciun motiv bateriile în gură pentru a evita ingerarea accidentală a acestora Ingerarea bateriilor poate cauza sufocarea şi sau intoxicarea Instalaţi unitatea pe o structură rigidă pentru a preveni producerea unui nivel excesiv de sunete sau vibraţii Nivelul de presiune acustică po...

Page 18: ...Viale Colleoni 7 20864 Agrate Brianza MB Italy Norwegian Branch Gneisveien 2D 1914 Ytre Enebakk Norway Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Sollentuna Sweden UK Branch Travellers Lane Hatfield Herts AL10 8XB England U ...

Reviews: