74
Outdoor noise filter circuit board
PUMY-P100YHMB(-BS) PUMY-P100YHMBR1(-BS) PUMY-P100YHMBR2(-BS)
PUMY-P125YHMB(-BS) PUMY-P125YHMBR1(-BS) PUMY-P125YHMBR2(-BS)
PUMY-P140YHMB(-BS) PUMY-P140YHMBR1(-BS) PUMY-P140YHMBR2(-BS)
LI1, LI2, LI3, NI
POWER SUPPLY
LI1-LI2/LI2-LI3/LI3-LI1 : AC380/400/415V input
LI1-NI/LI2-NI/LI3-NI : AC220/230/240V input
(Connect to the terminal block (TB1))
GD1
Connect to the earth
CNAC2
AC220/230/240V
(Connect to the
outdoor controller
circuit board (CNAC))
CNDC
(Connect to the
outdoor controller
circuit board (CNDC))
LO1, LO2, LO3
POWER SUPPLY
LO1-LO2/LO2-LO3/LO3-LO1 : AC380/400/415V OUTPUT
(Connect to the outdoor converter circuit board and ACL (L1-IN, ACL2, ACL3))
CNCT
Primary current
(Connect to the
outdoor power
circuit board (CN5))
NO
Connect to the
outdoor converter
circuit board. (N-IN)
CNL
Connect to the ACL4
CNAC1
AC220/230/240V
(Connect to the outdoor transmission power
board(CN1))
GD3
Connect to the earth