163
9. OPTIONAL PARTS
HEAT SOURCE
WR2
MEE15K036
9-2. OUTDOOR TWINNING KIT
The following optional Outdoor Twinning Kit is needed to use to combine multiple refrigerant pipes. Refer to the chapter entitled
System Design Section for the details of selecting a proper twinning kit.
CMY-Q100CBK2
(1-7/16)
ø19.05(ø3/4)
ø19.05(ø3/4)
ø25.4(ø1)
ø28.58(ø1-1/8)
ø22.2(ø7/8)
ø28.58(ø1-1/8)
ø28.58(ø1-1/8)
ø19.05(ø3/4)
ø19.05(ø3/4)
ø22.2(ø7/8)
ø22.2(ø7/8)
ø34.93(ø1-3/8)
ø28.58(ø1-1/8)
ø22.2(ø7/8)
(Outside diameter)
(Outside diameter)
(Outside diameter)
Low-pressure pipe twinning kit
High-pressure twinning pipe
<Pipe for routing through the front (Accessory)>
On-site pipes
Inclination tolerance of the
relative to the ground.
High-pressure twinning pipe
Note 1. Refer to the figure below for the installation
position of the high-pressure twinning pipe.
2. Pipe diameter is indicated
by inside diameter.
(1-15/16)
(6/16)
high-pressure twinning pipe is ±15°
(2-9/16)
(2-1/8)
<Accessory>
Fixing screw
Insulation cover
Pipe cover (150mm(5-15/16) Length)
Pipe cover (60mm(2-3/8) Length)
Cable tie
Water stopper
Sealing material (Small)
Sealing material (Large)
• • • 1
• • • 1
• • • 2
• • • 1
• • • 2
• • • 1
• • • 1
• • • 1
Pipe cover (80mm(3-3/16) Length)
• • • 2
<Elbow pipe(Accessory)>
<Pipe for routing through the front (Accessory)>
315(12-7/16)
27(1-2/16)
45(1-13/16)
35
±15°
144(5-1
1/16)
65
53
25(1)
50(2)
49
9
169(6-1
1/16)
50(2)
50(2)
36(1-7/16)
36(1-7/16)
80(3-3/16)
135(5-1/4)
187(7-6/16)
CMY-Q200CBK
Low-pressure pipe twinning kit
High-pressure twinning pipe
On-site pipes
Inclination tolerance of the
relative to the ground.
High-pressure twinning pipe
Note 1. Refer to the figure below for the installation
position of the high-pressure twinning pipe.
2. Pipe diameter is indicated
by inside diameter.
high-pressure twinning pipe is ±15°
±15°
<Accessory>
Fixing screw
Insulation cover
Pipe cover (75mm(3) Length)
Pipe cover (360mm(14-3/16) Length)
Cable tie
Water stopper
Sealing material (Small)
Sealing material (Large)
• • • 1
• • • 1
• • • 1
• • • 1
• • • 2
• • • 1
• • • 1
• • • 1
Pipe cover (70mm(2-13/16) Length)
• • • 1
Pipe cover (130mm(5-1/8) Length)
Pipe cover (100mm(3-15/16) Length)
• • • 1
• • • 1
Pipe cover (160mm(6-5/16) Length)
• • • 1
(1-7/16)
ø19.05(ø3/4)
ø28.58(ø1-1/8)
ø31.75(ø1-1/4)
ø28.58(ø1-1/8)
ø28.58(ø1-1/8)
ø28.58(ø1-1/8)
ø19.05(ø3/4)
ø19.05(ø3/4)
ø31.75(ø1-1/4)
ø31.75(ø1-1/4)
ø22.2(ø7/8)
ø19.05(ø3/4)
ø28.58(ø1-1/8)
(Outside diameter)
(Outside diameter)
(Outside diameter)
<Deformed pipe(Accessory)>
<Pipe for routing through the front (Accessory)>
<Elbow pipe(Accessory)>
(2-3/4)
(2-1/2)
(2-1
1/16)
(2-5/8)
ø25.4(ø1)
ø28.58(ø1-1/8)
ø28.58(ø1-1/8)
(Outside diameter)
ø41.28(ø1-5/8)
ø34.93(ø1-3/8)
ø34.93(ø1-3/8)
ø31.75(ø1-1/4)
(Outside diameter)
(Outside diameter)
<Pipe for routing through the front (Accessory)>
407(16-1/16)
72(2-7/8)
35
31(1-1/4)
1
14(4-1/2)
169(6-1
1/16)
50(2)
50(2)
53(2-1/8)
53(2-1/8)
80(3-3/16)
62
77(3-1/16)
215(8-1/2)
160(6-5/16)
69
185(7-5/16)
68
38(1-1/2)
66
50(2)
104(4-1/8)
Slope of the twinning pipe is at an angle
within to the horizontal plane.
2. Use the attached pipe to braze the port-opening of the distributer.
3. Pipe diameter is indicated by inside diameter.
Note 1. Refer to the figure below for the installation
position of the twinning pipe.
Twinning pipe on the
high-pressure side
15
15
4. Only use the Twinning pipe by Mitsubishi (optional parts) .
0000003811.BOOK 163 ページ 2015年11月9日 月曜日 午前11時20分