8
GB
Ŷ
&RQ¿UPDWLRQSURFHGXUH
F1
F2
F3
F4
Manual vane angle
Input display:
Cur.
Address
Check
M-NET address
Identify unit Check button
F1
F2
F3
F4
Manual vane angle
Input display:
M-NET address
The air conditioner with the
vane pointing downward is
the target air conditioner.
F1
F2
F3
F4
Manual vane angle
Input display:
There is no response from
the target device.
Confirm the state of the air
conditioner.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
3.6. Ventilation
For LOSSNAY combination
Ŷ
The following 2 patterns of operation is available.
5XQWKHYHQWLODWRUWRJHWKHUZLWKLQGRRUXQLW
5XQWKHYHQWLODWRULQGHSHQGHQWO\
3. Operation
F1
F2
F3
F4
Manual vane angle
Input display:
Cur.
Address
Check
M-NET address
Identify unit Check button
F1
F2
F3
F4
Manual vane angle
Manual vane angle
Select:
Setting
Outlet
Angle
MITSUBISHI ELECTRIC
LABEL
Ŷ
Vane setting
Step 1
Step 2
Step 4
Step 3
No setting
All outlets
Step 5
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 4) when
the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
will be displayed the next time
the unit goes into operation.
Navigating through the screens
To go back to the Main menu ................ [MENU] button
To return to the previous screen .......... [RETURN] button
1
Select the "M-NET address" for
the units to whose vanes are
to be fixed, with the [F2] or [F3]
button. Press the [F4] button to
FRQ¿UPWKHXQLW
2
After pressing the [F4] button,
wait approximately 15 seconds,
and then check the current state
of the air conditioner.
ĺ7KHYDQHLVSRLQWLQJ
GRZQZDUGĺ7KLVDLUFRQGLWLRQHU
is displayed on the remote
controller.
ĺ$OORXWOHWVDUHFORVHGĺ
Press the [RETURN] button and
continue the operation from the
beginning.
ĺ7KHPHVVDJHVVKRZQWRWKH
OHIWDUHGLVSOD\HGĺ7KHWDUJHW
device does not exist at this
address.
3UHVVWKH>5(7851@EXWWRQWR
return to the initial screen.
3
Change the "M-NET address" to
the next number.
5HIHUWRVWHS
1
to change the
"M-NET address" and continue
with the confirmation.
4. Timer
Ŷ
Timer functions are different by each remote controller.
Ŷ
For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.
3
Select the "M-NET address" for
the units to whose vanes are
to be fixed, with the [F2] or [F3]
button, and press the [SELECT]
button.
Press the [F4] button to confirm
the unit.
The vane of only the target indoor
unit is pointing downward.
4
The current vane setting will
appear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] but-
ton.
2XWOHWDQG
4, (all outlets)"
Press the [F3] or [F4] button to go
through the option in the order of
"No setting (reset)," "Step 1", "Step
2", "Step 3", "Step 4" and "Step 5".
Select the desired setting.