Mitsubishi Electric PEFY-P-VMS-E Installation Manual Download Page 1

Air-Conditioners
INDOOR UNIT

PEFY-P-VMS-E

GB

PO

HG

SV

CZ

TR

RU

GR

P

NL

I

E

F

D

SL

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.

INSTALLATIONSHANDBUCH

Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.

MANUEL D’INSTALLATION

Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte.

MANUAL DE INSTALACIÓN

Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d’aria.

INSTALLATIEHANDLEIDING

Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.

MANUAL DE INSTALAÇÃO

Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.

E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™

°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.

РУКОВОДСТВО ПО УСТАНОВКЕ

Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.

MONTAJ ELK‹TABI

Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.

Summary of Contents for PEFY-P-VMS-E

Page 1: ...o sicuro e corretto leggere attentamente questo manuale di installazione prima di installare il condizionatore d aria INSTALLATIEHANDLEIDING Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert MANUAL DE INSTALAÇÃO Para segurança e utilização correctas leia atentamente este manual de instalação antes de instalar a unidade de ...

Page 2: ...of gravity A Access door B Electrical parts box C Air inlet D Air outlet E Ceiling surface F Service space viewed from the side G Service space viewed from the direction of arrow 1 600 mm or more 2 100 mm or more 3 20 mm or more 4 300 mm or more A Indoor unit s bottom surface Y X L W A Z B A A A B C D 270 170 102 48 270 116 70 Model PEFY P20 25 32 40VMS E PEFY P50VMS E PEFY P63VMS E A 900 1100 B 9...

Page 3: ...F Indoor unit G Make the piping size large for grouped piping H Downward slope 1 100 or more I O D ø38 PVC TUBE for grouped piping 9 mm or more insulation J Up to 550 mm N Drain hose accessory O Horizontal or slightly upgradient 7 2 Fig 7 2 2 C B A L D D D E K M B H I Max 20m 1 5 2m G F F F B C D E E H G K J F I A 25 35 25 A Indoor unit B Insulation pipe accessory C Tie band accessory D Visible pa...

Page 4: ...protection 16 A C Indoor unit D Total operating current be less than 16 A E Pull box A Terminal block for indoor transmission cable B Terminal block for outdoor transmission cable C Remote controller A Non polarized B TB15 C Remote Controller D TB5 Fig 9 2 3 Fig 9 2 4 2 S M2 M1 A B D 1 DC10 13V A B 1 2 L N C D A S M2 M1 B 1 2 L N DC24 30V A B 1 2 C 9 2 Fig 7 3 1 7 3 A B F C D E A Insert pump s end...

Page 5: ...ntroller terminal bed for indoor unit and BC controller A Terminal bed B Round terminal C Shield wire D The earth wire from two cables are connected together to the S terminal Dead end connection E Insulation tape To keep the earth wire of the shielded cable from coming in contact with the transmis sion terminal CN62 SW1 MADE IN JAPAN ON SW14 N0 N0 W254613G03 FP AD R JP2 JP3 JP4 CN82 8 1 6 1 10 1 ...

Page 6: ...ferent refrigerant or air is mixed with the original refrigerant the refrig erant cycle may malfunction and the unit may be damaged If the air conditioner is installed in a small room measures must be taken to prevent the refrigerant concentration from exceeding the safety limit even if the refrigerant should leak Consult the dealer regarding the appropriate measures to prevent the safety limit fr...

Page 7: ...nd fuse of the specified capacity A fuse or circuit breaker of a larger capacity or a steel or copper wire may result in a general unit failure or fire Do not wash the air conditioner units Washing them may cause an electric shock Be careful that the installation base is not damaged by long use If the damage is left uncorrected the unit may fall and cause personal injury or property damage Install...

Page 8: ...olts and anti quake supporting members field supply 5 Installing the unit 5 1 Hanging the unit body s s s s s Bring the indoor unit to an installation site as it is packed s s s s s To hang the indoor unit use a lifting machine to lift and pass through the hanging bolts Fig 5 1 1 P 2 A Unit body B Lifting machine Fig 5 1 2 P 2 C Nuts field supply D Washers field supply E M10 hanging bolt field sup...

Page 9: ...he refrigerant pipe from an outdoor unit is received by BC controller and branches at the BC controller to connect between indoor units For constraints on pipe length and allowable difference of elevation refer to the outdoor unit manual The method of pipe connection is brazing connection Caution Install the refrigerant piping for the indoor unit in accordance with the following 1 Cut the tip of t...

Page 10: ...on cables Types of transmission cables Design wiring in accordance with the following table Table 1 Cable diameter More than 1 25 mm2 8 Duct work When connecting ducts insert a canvas duct between the main body and the duct Use non combustible duct components Install sufficient thermal insulation to prevent condensation forming on outlet duct flanges and outlet ducts Caution Keep the distance betw...

Page 11: ...wiring Power supply cords of appliances shall not be lighter than design 245 IEC 57 or 227 IEC 57 A switch with at least 3 mm contact separation in each pole shall be provided by the Air conditioner installation Power cable size more than 1 5 mm2 Fig 9 1 1 P 4 A Switch 16 A B Overcurrent protection 16 A C Indoor unit D Total operating current be less than 16 A E Pull box Selecting non fuse breaker...

Page 12: ... for over 10 at 0 and match SW11 for 1 to 9 with 3 2 How to set branch numbers SW14 Series R2 only The branch number assigned to each indoor unit is the port number of the BC controller to which the indoor unit is connected Leave it to 0 on the non R2 series of units The rotary switches are all set to 0 when shipped from the factory These switches can be used to set unit addresses and branch numbe...

Page 13: ...ess telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Reviews: