APPX
Appendix 2 Remote Register
243
A
Output Y OFF information clear request
■
Device number
■
Description
This remote register is used to clear Output Y OFF information Y
(RWrE, RWrF). (
Page 176 Output OFF information)
■
Output Y OFF information clear request Y0 to YF (RWwE)
■
Output Y OFF information clear request Y10 to Y1F (RWwF)
Synchronization output timing setting
■
Device number
■
Description
When the synchronization cycle timing control mode is used, set the output timing relative to the synchronization cycle start
timing.
Set the timing to change the output from OFF to ON, or from ON to OFF in one synchronization cycle.
If the values set in Synchronization output timing setting Y
OFF to ON (RWw10, RWw11, ... , RWw8C, RWw8D) and
Synchronization output timing setting Y
ON to OFF (RWw12, RWw13, ... , RWw8E, RWw8F) are the same for one output,
the output does not change.
■
Setting value
Set the time (unit: ns) taken from the synchronization cycle start timing to the output change.
The following table lists the setting values.
Name
Device number
Output Y OFF information clear request
RWwE, RWwF
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
YF
YE
YD
YC
YB
YA
Y9
Y8
Y7
Y6
Y5
Y4
Y3
Y2
Y1
Y0
Off: Output Y OFF information is not cleared.
On: Output Y OFF information is cleared.
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Y1F
Y1E
Y1D
Y1C
Y1B
Y1A
Y19
Y18
Y17
Y16
Y15
Y14
Y13
Y12
Y11
Y10
Off: Output Y OFF information is not cleared.
On: Output Y OFF information is cleared.
Name
Device number
Synchronization output timing setting Y
RWw10 to RWw8F
Setting value
Description
0 to 4294967294 (00000000H to FFFFFFFEH)
The output changes at preset timing.
4294967295 (FFFFFFFFH)
The output does not change.