14
4
SPECIFICATIONS
Single, 50Hz, 220/230/240V, Single, 60Hz, 220V
Munsell 3Y 7.8/1.1
Linear Expansion Valve (In branch box)
Hermetic
ANB33FDCMT
Line start
HP switch, LP switch, Discharge thermo
—
Plate fin coil
Propeller fan
o
2
0.060 +0.060
100 (3,530)
Reverse cycle
50
52
950 (37-3/8)
330+30 (13+1-3/16)
1,350 (53-1/8)
128 (282)
R410A
8.5 (18.7), 40m
2.3 (MEL56)
[
9.52
[
15.88
Flared
Flared
kW
W
kW
K
/min (CFM)
dB
dB
mm (in.)
mm (in.)
mm (in.)
kg (lbs)
kg (lbs)
L
mm
mm
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C (80˚F), W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C (95˚F), W.B. 24˚C (75˚F)
Heating : Indoor
: D.B. 20˚C (68˚F)
Outdoor : D.B. 7˚C (45˚F), W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : Main Piping (From outdoor unit to branch box) : 5m
Branch Piping (From branch box to each indoor units) : each 3m
2. Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
M-series, S-series
D.B. 32˚C, W.B. 23˚C
D.B. 21˚C, W.B. 15˚C
D.B. 27˚C
D.B. 20˚C
P-series
D.B. 35˚C, W.B. 22.5˚C
D.B. 19˚C, W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. –5˚C
D.B. 21˚C, W.B. 15˚C
D.B. –15˚C, W.B. –15˚C
Cooling
Heating
Service Ref.
2.9
OUTDOOR UNIT
REFRIGERANT PIPING
MXZ-8A140VA/ MXZ-8A140VA
1
/ MXZ-8A140VA
2
/ MXZ-8A140VA
3
Power supply (phase, cycle, voltage)
Breaker
Max. current (Outdoor unit only)
Conversion formula:
Conversion formula
kcal/h = kW
o
860
Btu/h = kW
o
3412
CFM
= m
3
/min
o
35.31
[
6.35mm
1/4 inch
[
9.52mm
3/8 inch
[
12.7mm
1/2 inch
[
15.88mm
5/8 inch
[
19.05mm
3/4 inch
Indoor
3. Guaranteed voltage
198~264V, 50Hz 198~242V, 60Hz
4. Above data are based on the indicated voltage.
Single, 50Hz, 220/230/240V, Single, 60Hz, 220V
5. Refer to the service manual of indoor unit for the indoor unit's specifications.
14.0
3.79
17.30/16.55/15.86, 17.30
99.6
14
16.0
3.90
17.82/17.05/16.33, 17.82
99.5
14
Please refer to "10.ELECTRICAL WIRING".
29.5
Standard performance
Rated Cooling capacity
Rated power consumption
w
1
Operating current
w
1
Operating power factor
w
1
Starting current (Outdoor unit)
Rated Heating capacity
Rated power consumption
w
1
Operating current
w
1
Operating power factor
w
1
Starting current (Outdoor unit)
kW
kW
A
%
A
kW
kW
A
%
A
A
Heating
Cooling
w
1 In case of connecting 3 indoor units (6.0kW class), electrical data is only for outdoor unit.
• Outdoor unit : MXZ-8A140VA
MXZ-8A140VA
1
MXZ-8A140VA
2
MXZ-8A140VA
3
OC316D--1.qxp 07.8.24 2:11 PM Page 14