31
Strainer
#100
Power
receiver
LEV A
LEV B
LEV C
Oil separator
Compressor
Defrost
thermistor RT61
Distributor
Muffler
4-way
valve
LEV E
Indoor unit
A
Indoor unit
B
Indoor unit
C
Indoor unit
A
Indoor unit
B
Indoor unit
C
Capillary tube
Capillary tube
Charge pipe
Capillary tube
Capillary tube
Capillary tube
Discharge
temperature
thermistor RT62
Strainer
#100
Strainer
#100
Strainer
#100
R.V. coil
OFF
ON
Refrigerant flow in cooling
Refrigerant flow in heating
Ambient
temperature
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor
RT68
FAN-OUT
HEX-OUT
Strainer
#100
Stop valve with
service port
Stop valve
High-pressure switch
UNIT: mm (inch)
UNIT: mm
MXZ-3F54VF
Outdoor unit union diameter
For
Indoor unit A
Liquid
6.35(1/4)
Gas
9.52(3/8)
Indoor unit B
Liquid
6.35(1/4)
Gas
9.52(3/8)
Indoor unit C
Liquid
6.35(1/4)
Gas
9.52(3/8)
a
b
c
Outdoor
unit
Indoor
units
15 m
10 m
15 m
Max.
Height
difference
MAX REFRIGERANT PIPING LENGTH
Piping length each indoor unit (a, b, c)
25 m
Total piping length (a+b+c)
50 m
Bending point for each unit
25
Total bending point
50
It is irrelevant which unit is higher.
Refrigerant pipe diameter is different according to indoor unit to be
connected. When using extension pipes, refer to the right table.
When diameter of refrigerant pipe is different from that of outdoor
unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe, refer to "PARTS
CATALOG".
ADDITIONAL REFRIGERANT CHARGE
Refer to "Method of charging refrigerant".
Outdoor unit
precharged
(g)
Refrigerant piping length (one way, 3 unit total)
50 m
1,400
0
OBH790
Summary of Contents for MXZ-2F33VF
Page 22: ...22 OUTLINES AND DIMENSIONS 6 MXZ 2F33VF MXZ 2F42VF MXZ 2F53VF MXZ 2F53VFH Unit mm OBH790 ...
Page 25: ...25 WIRING DIAGRAM 7 MXZ 2F33VF E1 ET1 MXZ 2F42VF E1 ET1 MXZ 2F53VF E1 ET1 OBH790 ...
Page 26: ...26 MXZ 2F53VFH E1 OBH790 ...
Page 27: ...27 MXZ 3F54VF E1 ET1 MXZ 3F68VF E1 ET1 OBH790 ...
Page 28: ...28 MXZ 4F72VF E1 ET1 OBH790 ...
Page 93: ...93 OBH790 ...