13
9-2. CAPACITY AND INPUT CORRECTION BY OPERATIONAL FREQUENCY OF COMPRESSOR
0
50
100
0.5
1.0
1.5
0
50
100
0.5
1.0
1.5
2.0
0
50
100
150
0.5
1.0
1.5
0
50
100
150
0.5
1.0
1.5
2.0
MUZ-AP20VG
Correction of Cooling capacity
The operational frequency
of compressor (Hz)
C
ap
ac
ity
c
or
re
ct
io
n
fa
ct
or
s
Correction of Cooling input
The operational frequency
of compressor (Hz)
In
pu
t c
or
re
ct
io
n
fa
ct
or
s
Correction of Heating capacity
The operational frequency
of compressor (Hz)
C
ap
ac
ity
c
or
re
ct
io
n
fa
ct
or
s
Correction of Heating input
The operational frequency
of compressor (Hz)
In
pu
t c
or
re
ct
io
n
fa
ct
or
s
15
20
25
30
35
0.4
0.5
0.6
0.7
0.8
0.9
(kgf/cm
2
[Gauge])(MPa [Gauge])
6
5
4
7
8
9
50
60
70
Ambient temperature(°C)
Ambient humidity(%)
Outdoor low pressure
MUZ-AP20VG
COOL operation
Both indoor and outdoor unit are under the same temperature/
humidity condition.
Operation: TEST RUN OPERATION (Refer to 9-3.)
9-4. OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT
Dry-bulb temperature (°C) Relative humidity (%)
20
50
25
60
30
70
9-3. HOW TO OPERATE FIXED-FREQUENCY OPERATION
<Test run operation>
1. Press EMERGENCY OPERATION switch to start COOL or HEAT mode (COOL: Press once, HEAT: Press twice).
2. Test run operation starts and continues to operate for 30 minutes.
3. Compressor operates at rated frequency in COOL mode or 58 Hz in HEAT mode.
4. Indoor fan operates at High speed.
5. After 30 minutes, test run operation finishes and EMERGENCY OPERATION starts (operation frequency of compressor varies).
6. To cancel test run operation (EMERGENCY OPERATION), press EMERGENCY OPERATION switch or any button on
remote controller.
NOTE
:
The unit of pressure has been changed to MPa on the international system of units (SI unit system)
The conversion factor is:
1 (MPa [Gauge]) = 10.2 (kgf/cm
2
[Gauge])
OBH839A