DISASSEMBLY INSTRUCTIONS
24
10
10-1. MUCF-GA35VB
OPERATING PROCEDURE
PHOTOS
1. Removing the cabinet
(1) Remove the screws of the top panel.
(2) Remove the screw of the service panel.
(3) Remove the screws of the cabinet.
(4) Remove the screws of the front panel and motor support.
(5) Remove the service panel, and remove the screw from
the insides.
(6) Remove the top panel.
(7) Remove the cabinet.
Photo 1
Photo 3
Screws of the
top panel
Service
panel
Screws of the
service panel
Screws of the
top panel
Screws of the
cabinet
Screws of the cabinet
Photo 2
Screws of the front panel and motor support
Screws
of the
cabinet
(1) Slide the sleeve and check if there is a locking lever or not.
(2) The terminal with this connector has the locking
mechanism.
1
Slide the sleeve.
2
Pull the terminal while
pushing the locking
lever.
1
Hold the sleeve, and
pull out the terminal
slowly.
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
<"Terminal with locking mechanism" Detaching points>
Connector
Sleeve
Locking lever
OB383A--1.qxp 06.5.9 7:08 PM Page 24