Job Name: 

Location: 

Date:

Purchaser: 

Engineer:

Submitted to: 

For       Reference       Approval       Construction

System Designation: 

Schedule No.: 

  

Zoning

Cooling*

Rated Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/h

Total Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 W

Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.57 A

Heating*

Rated Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13,600 Btu/h

Total Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 W

Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.46 A

Rating  Conditions  (Cooling)  -  Indoor:  80ºF  (27ºC)  DB  /  67ºF  (19ºC)  WB.

Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB.

(Heating) - Indoor: 70ºF (21ºC) DB / 60ºF (16ºC) WB. Outdoor: 47ºF (8ºC) DB / 

43ºF (6ºC) WB. 

(For data on specific indoor units [all ducted, all non-ducted, and both ducted 

and non-ducted] combinations, see the MXZ Technical and Service Manual.)

Electrical Requirements

Power Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 Hz

MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A

Voltage

Indoor - Outdoor S1-S2  . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230V

Indoor - Outdoor S2-S3  . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC 24V

Indoor Unit: SEZ-KD12NA

Fan

Type x Quantity. . . . . . . . . . . . . . . . . . . . . . . . . . . . Sirocco Fan x 2

Motor  . . . . . . . . . . . . . . . . . . . . . Direct-driven DC Brushless Motor

Motor Output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96  W

Airflow (Lo - Med - Hi). . . . . . . . . . . . . . . . . . . 247 - 317 - 388 CFM

Air Filter  . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene  Honeycomb

External Static Pressure. . . . . . . . . . . 0.02 - 0.06 - 0.14 - 0.20

"

WG

Sound Pressure Level (Lo - Med - Hi) . . . . . . . . .23 - 28 - 33 dB(A)

DIMENSIONS

UNIT INCHES / MM

39 / 990

D

27-9/16 / 700

H

7-7/8 / 200

Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  46 lbs. / 21 kg 

Field Drainpipe Size O.D.. . . . . . . . . . . . . . . . . . . . . 1-1/4" / 32 mm

Wall-mounted Remote Controller . . . . . . . . . . . . . . . . . PAR-21MAA

(See Data Submittal Sheet)

Refrigerant Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410A

Refrigerant Pipe Size O.D.

   Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mm

   Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4" / 6.35 mm

Connection Method  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Flared

SUBMITTAL DATA: SEZ-KD12NA

         

12,000 BTU/H HORIZONTAL-DUCTED INDOOR UNIT FOR MXZ MULTI-ZONE HEAT-PUMP SYSTEMS

Remote Controller: PAR-21MAA

OPTIONAL ACCESSORIES

• M-NET Control Adapter (MAC-399IF)

• External Heat Adapter (PAC-YU25HT)

• CN24 Relay Kit (CN24RELAY-KIT-CM)

• Three-pole Disconnect Switch (TAZ-MS303)

GENERAL FEATURES

• Ceiling-concealed ducted indoor unit for residential applications

• Ultra thin body: 7-7/8

"

 high

• Built-in drain mechanism for condensate removal; lifts to 21-11/16

"

• Air filter is included with indoor unit

• Quiet operation ― as low as 23 dBA

• PAR-21MAA wired remote controller is included

• Indoor unit powered from outdoor unit using A-Control

• Automatic fan speed control

• Auto restart following a power outage

• Limited warranty: five years on parts and defects and seven years on 

compressors

SEZ-KD and PEAD-A24

MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE:

• Ducted Indoor Units:  

  

SEZ-KD09,12,15,18NA, PEAD-A24AA

• Nonducted Indoor Units:  

  

MSZ-GE06,09,12,15,18NA, MSZ-GA24NA,

  MSZ-FE09,12NA, MFZ-KA09,12,18NA, 

 

  PCA-A24KA, and PLA-A12,18,24BA

• A combination of both Ducted and Nonducted 

  Indoor Units

Refer to the separate submittal forms for the  

MSZ-GE, MSZ-GA, MSZ-FE, SEZ-KD, PEAD, 

PCA, PLA Indoor Units, and MXZ Outdoor Units.

Outdoor Unit: MXZ-3B30NA

PCA-KA

PLA-A12,18,24BA

Remote Controller PAR-21MAA - Packaged 

with PCA-KA, PLA-ABA, SEZ, and PEAD

MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS

Wireless Remote Controller -  

Packaged with MSZ-GE, -GA, 

-FE and MFZ-KA (Optional Wired 

Remote Controller PAR-21MAA)

MFZ-KA

MSZ-GE06,09,12,15,18NA and MSZ-GA24NA

MSZ-FE