47
Parts name
Check points
Disconnect the connector then measure the resistance with a tester.
(At the ambient temperature 10
~30
, 50°F~86°F)
Thermistor (TH3)
<Outdoor pipe>
Thermistor (TH6)
<Outdoor 2-phase pipe>
Thermistor (TH7)
<Outdoor>
Thermistor (TH8)
<Heatsink>
Thermistor (TH32)
<Shell>
Normal
160k
~410k
4.3k
~9.6k
39k
~105k
TH32
TH3
TH6
TH7
TH8
Abnormal
Open or short
Measure the resistance between the terminals with a tester.
(At the ambient temperature 20
, 68°F)
Solenoid valve coil
<Four-way valve>
(21S4)
Motor for compressor
(MC)
1
2
3
4
5
6
M
Gray
Orange
Red
Yellow
Black
Linear expansion valve
(LEV-A)
Normal
Abnormal
Open or short
A42
Disconnect the connector then measure the resistance with a tester.
(Winding temperature 20
, 68°F)
Refer to next page.
Fan motor (MF1,MF2)
2350
$
170
A42
0.302
Measure the resistance between the terminals with a tester.
(Winding temperature 20
, 68°F)
Normal
Abnormal
Open or short
W
V
U
Normal
Gray - Black
Gray - Red
Gray - Yellow
Gray - Orange
Abnormal
46
$
3
Open or short
10-6. HOW TO CHECK THE PARTS
PUZ-A42NHA5 PUZ-A42NHA5-BS
PUY-A42NHA5 PUY-A42NHA5-BS
OCH512