19
Cooling only type (3)
NOTE:
1. Rating conditions (ISO T1)
Cooling : Indoor: D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F) W.B. 24
:
(75˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C
D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
4. Above data based on indicated voltage
Indoor unit
Single phase 230V 50Hz
Outdoor unit
Single phase 230V 50Hz, 3 phase 400V 50Hz
3. Guaranteed voltage
198~264V, 50Hz
5. Refer to the service manual of outdoor unit for tha outdoor
unit's specifications.
Weight
kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
kW
Service Ref.
Power supply (phase, cycle, voltage)
Input
kW
Running current
A
Starting current
A
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow
(Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
PLA-RP2.5AA.UK
Cooling
22,900
6,700
2.57
PLA-RP2.5AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.79
1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.070
14-15-16-18 (495-530-565-635)
0 (direct blow)
—
Remote controller & built-in
28-29-31-33
32 (1-1/4)
Outdoor unit Service Ref.
PU-P2.5VGAA.UK / PU-P2.5YGAA.UK
PU-P2.5VGAA
1
.UK / PU-P2.5YGAA
1
.UK
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53),
PANEL : 5 (11)
Weight
kg (lbs.)
Service Ref.
Item
Function
Capacity
Btu/h
W
Total input
kW
Service Ref.
Power supply (phase, cycle, voltage)
Input
kW
Running current
A
Starting current
A
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow
(Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level
(Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
Cooling
15,400
19,100
4,500
5,600
1.72
2.53
PLA-RP1.6AA.UK
PLA-RP2AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.16
0.79
0.79
1.0
1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.070
0.070
11-12-13-14 (390-425-460-495)
14-15-16-18 (495-530-565-635)
0 (direct blow)
—
Remote controller & built-in
27-28-29-31
28-29-31-33
32 (1-1/4)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53),
PANEL : 5 (11)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16), PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16), PANEL : 30 (1-3/16)
UNIT : 24 (53),
PANEL : 5 (11)
PU-P1.6VGAA.UK / PU-P1.6YGAA.UK
PU-P1.6VGAA
1
.UK / PU-P1.6YGAA
1
.UK
PU-P2VGAA.UK / PU-P2YGAA.UK
PU-P2VGAA
1
.UK / PU-P2YGAA
1
.UK
PLA-RP1.6AA.UK
PLA-RP2AA.UK
Outdoor unit Service Ref.
OC297-E-1.qxp 05.5.6 5:29 PM Page 19