15
Heat pump type (2)
Service Ref.
Item
Function
Capacity
Btu/h
W
kW
kW
Total input
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
A
Starting current
A
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow (Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level (Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
Weight
kg (lbs.)
PLA-RP1.6AA.UK
Cooling
Heating
15,400
16,900
4,500
4,950
1.72
1.70
PLA-RP1.6AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.16
0.79
0.79
1.0
1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.070
11-12-13-14(390-425-460-495)
0 (direct blow)
—
Remote controller & built-in
27-28-29-31
32 (1-1/4)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16) PANEL : 30 (1-3/16)
UNIT : 24 (53)
PUH-P1.6VGAA.UK / PUH-P1.6YGAA.UK
PUH-P1.6VGAA
1
.UK / PUH-P1.6YGAA
1
.UK
PANEL: 5 (11)
Outdoor unit Service Ref.
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F) W.B. 24
:
(75˚F)
Heating Indoor : D.B. 20
:
(68˚F)
Outdoor : D.B. 7
:
(45˚F)
W.B. 6
:
(43˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
Heating
Upper limit D.B. 28˚C
D.B. 24˚C, W.B. 18˚C
Lower limit D.B. 17˚C
D.B. -11˚C, W.B. -12˚C
4. Above data based on indicated voltage
Indoor unit
Single phase 230V 50Hz
Single phase 230V 50Hz / 3 phase 400V 50Hz
Outdoor unit
3. Guaranteed voltage
198~264V, 50Hz
5. Refer to the service manual of outdoor unit for tha outdoor
unit's specifications.
Service Ref.
Item
Function
Capacity
Btu/h
W
kW
kW
A
A
Total input
Service Ref.
Power supply (phase, cycle,voltage)
Input
Running current
Starting current
External finish (Panel)
Heat exchanger
Fan
Fan (drive)
o
No.
Fan motor output
kW
Airflow (Low-Medium2-Medium1-High)
K
/ min (CFM)
External static pressure
Pa (mmAq)
Booster heater
kW
Operation control & Thermostat
Sound level (Low-Medium2-Medium1-High)
dB
Unit drain pipe I.D.
mm (in.)
Dimensions
Indoor unit
W
mm (in.)
D
mm (in.)
H
mm (in.)
Weight
kg (lbs.)
PLA-RP2AA.UK
Cooling
Heating
19,100
21,700
5,600
6,350
2.53
2.20
PLA-RP2AA.UK
Single phase, 50Hz, 220-230-240V
0.16
0.16
0.79
0.79
1.0
1.0
Munsell 0.70Y 8.59/0.97
Plate fin coil
Turbo fan (direct)
o
1
0.070
14-15-16-18(495-530-565-635)
0 (direct blow)
—
Remote controller & built-in
28-29-31-33
32 (1-1/4)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 840 (33-1/16) PANEL : 950 (37-3/8)
UNIT : 258 (10-3/16) PANEL : 30 (1-3/16)
UNIT : 24 (53)
PANEL : 5 (11)
PUH-P2VGAA.UK / PUH-P2YGAA.UK
PUH-P2VGAA
1
.UK / PUH-P2YGAA
1
.UK
Outdoor unit Service Ref.