43
<How to operate>
To change the air flow direction, press
button.
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the discharge direction in automatically set to 10°. After, it can be changed to
another direction with
button on the remote controller.
<Auto return>
When 60° or 70° discharge is set with fan speed on LOW, “1Hr” appears below the room temperature display. One hour
later the direction changes to 10° degrees, automatically and “1Hr” disappears.
(2) HEAT operation
At the start-up of HEAT operation, discharge direction depends on the setting of the last operation.
After, it can be changed to another direction with
button. The discharge direction shifts to 10° regardless of the remote
controller settings under any of the following conditions.
●
Thermostat OFF
●
Defrosting
●
Indoor fan speed EXTRA-LOW in hot adjustment
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from LOW to HIGH during 30°
downward discharge in COOL mode, the direction auto-
matically changes to 10°.
10
°
30
°
60
°
70
°
Changes by pressing
the button.
SWING
2-5 Auto vane control
<Remote controller display>
FILTER
CHECK MODE
CHECK
TEST RUN