21
5
REFRIGRANT SYSTEM DIAGRAM
Indoor unit
Outdoor unit
Indoor coil
thermistor
RT2 or TH2
Refrigerant pipe
(Option)
5/8
(with heat insulator)
Distributor
Indoor
heat
exchanger
Outdoor
heat
exchanger
Refrigerant pipe
(Option)
3/8
(with heat insulator)
Flexible tube
Flared connection
Ball valve
Fusible
plug
High
Pressure
Switch
Outdoor coil
thermistor
TH3
Ball valve
Flow of refrigerant
(with service
port)
Flared connection
Accumulator
Compressor
Charge
plug
Check
plug
Strainer
Capillary tube
For PK12FK (
{
0.126
✕
{
0.071
✕
31.5)
Capillary tube size (OD
✕
ID
✕
Length)
For PK24FK (
{
0.126
✕
{
0.063
✕
17.3)
✕
2 sets
For PK18FK (
{
0.126
✕
{
0.063
✕
31.5)
✕
2 sets
Indoor unit
Outdoor unit
Indoor coil
thermistor
RT2 or TH2
Refrigerant pipe
(Option)
3/4
(with heat insulator)
Distributor
Indoor
heat
exchanger
Outdoor
heat
exchanger
Refrigerant pipe
(Option)
1/2
(with heat insulator)
Flexible tube
Flared connection
Ball valve
Fusible
plug
High
Pressure
Switch
Outdoor coil
thermistor
TH3
Ball valve
Flow of refrigerant
(with service
port)
Flared connection
Accumulator
Compressor
Charge
plug
Check
plug
Strainer
Capillary tube
For PK30FK (
{
0.157
✕
{
0.079
✕
29.1)
✕
2 sets
Capillary tube size (OD
✕
ID
✕
Length)
NOTE :The symbol indicates the diameter.
For PK36FK (
{
0.157
✕
{
0.079
✕
17.7)
✕
2 sets
PK12/18/24FK
PK30/36FK