background image

Air-Conditioners

PEAD-RP71, 100, 125, 140JAA

English

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

FOR USER

English

KD79D904H01_Cover.fm  Page 1  Friday, October 14, 2011  9:58 AM

Summary of Contents for Mr.Slim PEAD-RP100JALQ

Page 1: ...Air Conditioners PEAD RP71 100 125 140JAA English OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit FOR USER English ...

Page 2: ...anual details the suggested installation method Any structural alteration necessary for installation must comply with local building code requirements Never repair the unit or transfer it to another site by yourself If repair is performed improperly water leakage electric shock or fire may result If you need to have the unit repaired or moved consult your dealer The appliance is not intended for u...

Page 3: ...itable inside temperature is one that is within 5 C of the outside temperature Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air conditioner This could cause health problems Caution Do not direct the airflow at plants or caged pets Ventilate the room frequently If the unit is operated continu ously in a closed room for a long period of time the ...

Page 4: ...fter one hour at which time the airflow di rection also changes Room Temperature display Showstheroomtemperature Theroom temperature display range is 8 39 C The display flashes if the temperature is less than 8 C or 39 C or more Louver display Indicates the action of the swing louver Does not appear if the louver is station ary Power On indicator Indicates that the power is on Fan Speed indicator ...

Page 5: ...acing the remote controller install the holder included with the remote con troller on a wall and be sure to always place the remote controller in the holder after use Battery installation replacement 1 Remove the top cover insert two AAA batter ies and then install the top cover Top cover 2 Press the Reset button CLOCK CHECK RESET SET TESTRUN MODE FAN VANE LOUVER min h AUTOSTART AUTOSTOP ON OFF T...

Page 6: ... Selection of remote controller Set Day Time Standard Control Screens OFF ON Timer Monitor Timer Setup A D C B C B 1 Press the or Set Time button A to show display 2 2 Press the Timer On Off Set Day button 9 to set the day Each press advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button A as necessary to set the time As you hold the button down the time at 4 will incr...

Page 7: ...r as shown below 5 Operation To Stop Operation Press the ON OFF button 1 again The ON lamp 1 and the display area go dark Note Even if you press the ON OFF button immediately after shutting down the op eration is progress the air conditioner will not start for about three minutes This is to prevent the internal components from being damaged 5 2 Mode select Press the operation mode button 2 and sel...

Page 8: ...very day Example Operation 2 above which is the same for all days of the week Setting the Weekly Timer 5 Press the appropriate Set Time button A as necessary to set the de sired time at 5 As you hold the button down the time first increments in minute inter vals then in ten minute intervals and then in one hour intervals 6 Press the ON OFF button 1 to select the desired operation ON or OFF at 6 Ea...

Page 9: ... so that the time setting clears to at 4 If you want to use only an ON setting or only an OFF setting be sure that the setting you do not wish to use is shown as C C TIME SUN WEEKLY 0 C C TIME SUN WEEKLY 0 7 Press the appropriate Set Temperature button 3 to set the desired temperature at 7 Each press changes the setting in the following sequence No display no setting 24 25 29 30 12 23 No display A...

Page 10: ...is ON setting 5 hours OFF setting 2 hours 3 hours At Timer Start Display shows the timer s OFF setting hours remaining to OFF At 5 hours after timer start The air conditioner comes on and will continue to run until someone turns it off 6 1 3 Auto Off Timer This timer begins countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed Available settings ...

Page 11: ...the Filter button 4 press and hold down the ON OFF button 1 for 2 seconds so that the Locked indication disappears from the screen at 1 7 Other Functions C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CLEAR TEST TEMP MENU BACK DAY MONITOR SET CLOCK ON OFF 4 1 1 Lock Indicator 7 1 Locking the Remote Controller Buttons Operation function limit controller If you wish you can lock the r...

Page 12: ...can be changed using the remote controller function selection mode Change the setting when needed Item 1 1 Change Language CHANGE LANGUAGE 2 Function limit FUNCTION SELECTION 3 Mode selection MODE SELEC TION 4 Display change DISP MODE SETTING Item 2 Language setting to display 1 Operation function limit setting operation lock LOCKING FUNCTION 2 Use of automatic mode setting SELECT AUTO MODE 3 Temp...

Page 13: ...ection Display mode setting Operation lock setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting value The ...

Page 14: ...erlimitsettingandthelowerlimitsetting pressthe button H The selected setting will flash and the temperature can be set Settable range Cooling Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heating mode Lower limit 17 C 28 C Upper limit 28 C 17 C Automatic mode Lower limit 19 C 28 C Upper limit 28 C 19 C 4 3 Mode selection setting 1 Remote controller main sub setting To switch the setting pre...

Page 15: ...matic mode setting Temperature range limit setting Use of automatic filter elevation panel up down operation mode setting Use of fixed airflow direction mode setting Limit temperature cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer ...

Page 16: ...Caution In removing the filter precautions must be taken to protect your eyes from dust Also if you have to climb up on a stool to do the job be careful not to fall When the filter is removed do not touch the metallic parts inside the indoor unit otherwise injury may result PEAD RP JAA While lifting the filter knob pull it A Air intake B Air outlet C Filter D Knob Room air temperature display sett...

Page 17: ...nit draws in air that contains gases produced from the walls carpeting and furniture as well as odors trapped in clothing and then blows this air back into the room If the indoor temperature and the humidity are high this condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a mist During cooling mode water may form and drip from the cool pipes...

Page 18: ...higher than the noise specification which was measured in an echo free room The batteries are low Replace the batteries and press the Reset button If nothing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The self diagnosis function has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Tur...

Page 19: ...19 ...

Page 20: ...KD79D904H01 Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN ...