background image

Job Name: 

Location: 

Date:

Purchaser: 

Engineer:

Submitted to: 

For       Reference       Approval       Construction

System Designation: 

Schedule No.: 

  

Zoning

Cooling Capacity*

. . . . . . . . . . . . . . . . . . . . . . . . . . . .17,200 Btu/h

Heating Capacity*

. . . . . . . . . . . . . . . . . . . . . . . . . . . .21,600 Btu/h

Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF 

(35ºC) DB, 75ºF (24ºC) WB.

(Heating at 47ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB.

(For data on specific indoor units [all ducted, all non-ducted, and both ducted 

and non-ducted] combinations, see the MXZ-B Technical and Service Manual.)

Electrical Requirements

Power Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 Hz

MCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A

Voltage

Indoor - Outdoor S1-S2  . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230V

Indoor - Outdoor S2-S3  . . . . . . . . . . . . . . . . . . . . . . . . . DC 12-24V

Indoor - Remote Controller. . . . . . . . . . . . . . . . . . . . . . . . . Wireless

(Optional Wired Controller: DC 12V)

Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.76 F.L.A.

Airflow (Quiet - Lo - Med - Hi - Super Hi)

   Cooling . . . . . . . . . . . . . . . . . . . . .230 - 275 - 339 - 420 - 533 Dry CFM

194 - 240 - 304 - 385 - 498 Wet CFM

   Heating  . . . . . . . . . . . . . . . . . . . 230 - 275 - 339 - 431 - 512 CFM

Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi)

   Cooling  . . . . . . . . . . . . . . . . . . . . . . . . . 28 - 33 - 38 - 44 - 49 dB(A)

   Heating  . . . . . . . . . . . . . . . . . . . . . . . . . 28 - 33 - 38 - 43 - 48 dB(A)

DIMENSIONS

UNIT INCHES / MM

31-7/16 / 799

D

9-1/8 / 232

H

11-5/8 / 295

Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 lbs. / 10 kg

External Finish . . . . . . . . . . . . . . . . . . . . . . Munsell No. 1.0Y 9.2 / 0.2

Field Drainpipe Size O.D.. . . . . . . . . . . . . . . . . . . . . . 5/8" / 15.88 mm

Remote Controller  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wireless

(Optional Wired Remote Controller PAR-21MAA; 

see Data Submittal Sheet)

Refrigerant Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .R410A

Refrigerant Pipe Size O.D.

   Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" / 9.52 mm

   Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4" / 6.35 mm

Connection Method  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared

SUBMITTAL DATA: MSZ-GE18NA. . . . . .

18,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

OPTIONAL ACCESSORIES

• M-NET Control Adapter (MAC-399IF)

• MA Contact Terminal Interface (MAC-397IF)

• Wired Remote Controller (PAR-21MAA; requires MAC-397IF) 

• Condensate Pump (230V; SI3100-230)

• Anti-allergy Enzyme Filter (Two pieces per set; MAC-408FT-E)

GENERAL FEATURES

• Wall-mounted indoor unit

• Standard Hybrid Catechin Prefilter is included with indoor unit

• Quiet operation

• Choice of fan speeds: Quiet, Low, Medium, High, and Super High; 

  Auto fan speed control also included

• Wireless remote controller is included; PAR-21MAA wired 

  remote controller can be installed as an option

• Indoor unit powered from outdoor unit using A-Control

• Auto restart following a power outage

• Limited warranty: five years on parts and defects and seven years  

on compressors

Indoor Unit: MSZ-GE18NA

Wireless Remote Controller

MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS

SEZ-KD and PEAD-A24

Remote Controller PAR-21MAA - Packaged 

with PCA-KA, PLA-ABA, SEZ, and PEAD

MSZ-GE06,09,12,15,18NA and MSZ-GA24NA

MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE:

• Ducted Indoor Units:  

  

SEZ-KD09,12,15,18NA, PEAD-A24AA

• Nonducted Indoor Units:  

  

MSZ-GE06,09,12,15,18NA, MSZ-GA24NA,

  MSZ-FE09,12NA, MFZ-KA09,12,18NA,  

  PCA-A24KA, and PLA-A12,18,24BA

• A combination of both Ducted and Nonducted 

  Indoor Units

Refer to the separate submittal forms for the  

MSZ-GE, MSZ-GA, MSZ-FE, SEZ-KD, PEAD, 

PCA, PLA Indoor Units, and MXZ Outdoor Units.

Wireless Remote Controller -  

Packaged with MSZ-GE, -GA, 

-FE and MFZ-KA (Optional Wired 

Remote Controller PAR-21MAA)

Outdoor Unit: MXZ-3B30NA

MSZ-FE

MFZ-KA

PCA-KA

PLA-A12,18,24BA

Reviews: