1 SERVO PARAMETER DETAILS
1.8 Motor extension setting servo parameters group ([Pr. PL_ _ ])
149
1
1.8
Motor extension setting servo parameters group
([Pr. PL_ _ ])
[Pr. PL01_Function selection L-1 (**LIT1)]
Select a function of the linear servo motor or direct drive motor.
[Pr. PL01.0_Servo motor magnetic pole detection selection]
Select the magnetic pole detection method for the linear servo motor or direct drive motor.
0: Magnetic pole detection disabled
1: Magnetic pole detection at initial servo-on after cycling the power or after resetting the communication
5: Magnetic pole detection at every servo-on
The setting value "0" can be used on servo amplifiers with firmware version D0 or later when the fully closed loop system is
used with a Mitsubishi Electric-manufactured direct drive motor connected by the direct drive motor control mode.
Do not set any value other than "0", "1", and "5".
[Pr. PL01.2_Homing stop interval setting]
Select the stop interval at dog type homing.
This servo parameter is enabled only for linear servo motors.
0: 2
13
(= 8192) pulses
1: 2
17
(= 131072) pulses
2: 2
18
(= 262144) pulses
3: 2
20
(= 1048576) pulses
4: 2
22
(= 4194304) pulses
5: 2
24
(= 16777216) pulses
6: 2
26
(= 67108864) pulses
[Pr. PL02_Linear encoder resolution setting - Numerator (**LIM)]
Set the linear encoder resolution with [Pr. PL02] and [Pr. PL03].
Set a numerator in [Pr. PL02].
This servo parameter is enabled for linear servo motors.
Initial value
Setting range
Setting method
Ver.
00000301h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
1h
Refer to the text
A0
Initial value
Setting range
Ver.
3h
Refer to the text
A0
Initial value
Setting range
Setting method
Ver.
1000 [
μ
m]
1 to 65535
Each axis
A0