136
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF82_Drive recorder - Trigger operation selection (DRTM)]
[Pr. PF82.0_Drive recorder - Trigger mode selection]
Select the trigger mode for the drive recorder.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), the setting value of the
servo parameter is disabled.
0: Alarm trigger
1: Analog trigger/digital trigger
When "0" (alarm trigger) is set, trigger settings other than [Pr. PA23 Drive recorder desired alarm trigger setting] and [Pr.
PF84.4-5 Drive recorder - Trigger position setting] are disabled. Refer to the following table for the unavailable servo
parameters.
[Pr. PF82.1_Drive recorder - Trigger binding condition selection]
Select the trigger binding condition for the drive recorder.
When this servo parameter is set to "0" (disabled), the settings of [PF84.2-3 Drive recorder - Trigger channel selection 2] and
[PF86 Drive recorder - Trigger level setting 2] are disabled.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger), the setting value of this servo
parameter is disabled.
0: Disabled
1: Logical AND of trigger signals
2: Logical OR of trigger signals
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Servo parameter
Name
PF82.1
Drive recorder - Trigger binding mode selection
PF82.2
Drive recorder - Trigger operation selection 1
PF82.3
Drive recorder - Trigger operation selection 2
PF84.0-1
Drive recorder - Trigger channel selection 1
PF84.2-3
Drive recorder - Trigger channel selection 2
PF85
Drive recorder - Trigger level setting 1
PF86
Drive recorder - Trigger level setting 2
Initial value
Setting range
Ver.
0h
Refer to the text
A0