Parameter
Operation
MELSERVO J2-Super
4 - 13
Set the parameter value and switch power off once, then switch it on again to make that
parameter setting valid.
The values corresponds with the factory settings of the servo amplifier. Connecting it with
the servo system controller and switching power on changes them to the settings of the
servo system controller.
Setting and changing cannot be made from the peripheral software of the motion controller.
Function
No. Symbol
Name
Initial value
Unit
Customer
setting
Expansion
parameters
27
MO1
Analog output 1 offset
0
mV
28
MO2
Analog output 2 offset
0
mV
29
—
Reserved
0001
—
30
ZSP
Zero speed
50
r/min
31
ERZ
Error excessive alarm level
80
0.1 × r
32
OP5
Function selection 5
0000
—
33
OP6
Function selection 6
0000
—
34
VPI
PI-/PID control switch-over position
droop
0
Pulse
35
—
Reserved
0
—
36
VDC
Speed differential compensation
980
—
37
—
Reserved
0010
—
38
ENR
Encoder output pulses
4000
Pulse/r
39
—
Reserved
0
—
40
BLK
Parameter entry prohibition
0000
—
Tab. 4-12:
Parameter overview (2)
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......