Test operation mode
Operation
MELSERVO J2-Super
4 - 7
4.4
Test operation mode
By using a personal computer and the setup-software, you can execute jog operation,
positioning operation, motor-less operation and forced output without connecting the motion
controller.
Use the system setup according to fig. 3-28 and fig. 3-29.
●
JOG operation
Jog operation can be performed without using the servo system controller. This operation may
be used independently of whether the servo is on or off and whether the servo system controller
is connected or not.
Exercise control on the jog operation screen of the setup-software.
b
CAUTION:
●
The test operation mode is designed for servo operation confirmation and not for
machine operation confirmation. Do not use this mode with the machine. Always
use the servo motor alone.
●
If an operation fault occurred, use the forced stop (EM1) to make a stop.
NOTE
For full information of this functions, refer to the setup-software manual.
Initial value
Setting range
Speed [r/min]
200
0 to 5175
Acceleration/deceleration time constant [ms]
1000
0 to 20000
Tab. 4-5:
JOG operation settings
Function
Button
Forward rotation start
Forward
Reverse rotation start
Reverse
Stop
Stop
Tab. 4-6:
Operation method
Summary of Contents for MELSERVO MRJ2S-B
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ...VIII ...
Page 18: ...Contents XII ...
Page 48: ...Introduction System configuration 1 30 ...
Page 58: ...Installation General environmental conditions 2 10 ...
Page 86: ...Connection Station number setting 3 28 ...
Page 122: ...Operation Gain 4 36 ...
Page 134: ...Absolute position detection system General description 6 6 ...
Page 146: ...Accessories Special accessories 7 12 ...
Page 148: ...Maintenance and Inspection Life 8 2 ...
Page 174: ...Specifications Standard specifications 10 16 ...
Page 176: ...EMC Directives Requirements 11 2 ...
Page 198: ...Index iv ...
Page 199: ......