8 COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC AC SERVO PROTOCOL) [A]
8.4 Command and data No. list
413
8
Writing commands
Status display (command [8] [1])
Servo parameters (commands [9] [4]/[8] [5])
External I/O signals (command [9] [2])
Alarm history (command [8] [2])
Current alarm (command [8] [2])
I/O device prohibition (command [9] [0])
Command
Data No.
Description
Setting
range
Frame
length
[8] [1]
[0] [0]
Deleting status display data
1EA5
4
Command
Data No.
Description
Setting
range
Frame
length
[9] [4]
[0] [1] to [F] [F]
Writing servo parameters
The values of the parameters in the servo parameter group specified with the
command [8] [5] + data No. [0] [0] can be written. Always specify a servo
parameter group with the command [8] [5] + data No. [0] [0] before writing the
values.
The decimal converted from the data No. value (hexadecimal) corresponds to
the servo parameter No.
Differs
depending on
the servo
parameter.
12
[8] [5]
[0] [0]
Writing a servo parameter group
0000: Basic setting servo parameters ([Pr. PA_ _ ])
0001: Gain/filter servo parameters ([Pr. PB_ _ ])
0002: Extension setting servo parameters ([Pr. PC_ _ ])
0003: I/O setting servo parameters ([Pr. PD_ _ ])
0004: Extension setting 2 servo parameters ([Pr. PE_ _ ])
0005: Extension setting 3 servo parameters ([Pr. PF_ _ ])
000B: Motor extension setting servo parameters ([Pr. PL_ _ ])
0000 to 0005,
000B
4
Command
Data No.
Description
Setting
range
Frame
length
[9] [2]
[6] [0]
Communication input device signal
8
Command
Data No.
Description
Setting
range
Frame
length
[8] [2]
[2] [0]
Alarm history clear
1EA5
4
Command
Data No.
Description
Setting
range
Frame
length
[8] [2]
[0] [0]
Alarm clear
1EA5
4
Command
Data No.
Description
Setting
range
Frame
length
[9] [0]
[0] [0]
Turns off the input device, external analog input signal, and pulse train input,
except EM2, LSP and LSN, independently of the external on/off status.
1EA5
4
[0] [3]
Disables all output devices (DO).
1EA5
4
[1] [0]
Cancels the prohibition of the input device, external analog input signal and
pulse train input, except EM2, LSP and LSN.
1EA5
4
[1] [3]
Cancels the prohibition of the output device.
1EA5
4