392
7 NETWORK FUNCTION
7.2 Managing accounts
Setting an account
Set an account with MR Configurator2. Set the user information No. 1 account with [Pr. NPB04 User name No.1], [Pr. NPB05
Authorization level No.1], and [Pr. NPB06 Password No.1].
User name
Set a user name according to the following rule.
If no name (0 characters) is set in the user name, the account will be disabled, causing the network function to be unavailable.
Authorization level
The authorization level setting can be used to set whether accounts have the authority to use the network function. Set
"Permitted" in the authorization level setting to use the desired function. To prevent access to unnecessary functions, it is
recommended to set "Prohibited" for them. For details on the authorization level, refer to "User authentication parameters" in
the following manual.
MR-J5-G/MR-J5W-G User's Manual (Parameters)
MR-J5-A User's Manual (Parameters)
Password
Set a password in the password setting window. Double-clicking the network parameter input field will display the password
setting window. Enter the desired password in the password field and password (reentry) field, then click "OK" to set the
password.
Set a password according to the following rule.
Precautions
To prevent unauthorized access, it is recommended to change the default account.
Ensure that no duplicate user names are set among accounts. Accounts with duplicate user names may be unavailable.
To disable the account setting performed via an Ethernet connection, set [Pr. NPB01 User authentication and authorization
setting] to "1" (USB only). In the initial setting, the account setting is enabled via USB and Ethernet connection. For details,
refer to "User authentication parameters" in the following manuals.
MR-J5-G/MR-J5W-G User's Manual (Parameters)
MR-J5-A User's Manual (Parameters)
If the user name or password is forgotten, set it with MR Configurator2 again. When [Pr. NPB01] is set to "1" (USB only),
accounts cannot be set via an Ethernet connection. Set accounts via a USB connection.
Resetting network parameters to the factory setting will initialize accounts. Set accounts again.
Item
Usable character
Number of characters
1 to 32
Type of characters
• Single-byte letters (lowercase)
• Single-byte letters (uppercase)
• Single-byte numeric characters
Item
Usable character
Number of characters
4 to 32
Type of characters
• Single-byte letters (lowercase)
• Single-byte letters (uppercase)
• Single-byte numeric characters
• Special characters
"Special characters" refers to the following characters: `
~
! @ # $ %
^
& * ( ) _ + - = { } | ¥ : " ; ' < > ? , . / [ ] (additionally, a
single-byte space can be used).