132
3 BASIC FUNCTION
3.16 Electromagnetic brake interlock function
Setting method [A]
For specifications such as the power supply capacity and operation delay time of the electromagnetic brake,
refer to "Characteristics of electromagnetic brake" in the following manual.
Rotary Servo Motor User's Manual (HK series)
For a selection example of a surge absorber for the electromagnetic brake, refer to "Characteristics of
electromagnetic brake" in the following manual.
Rotary Servo Motor User's Manual (HK series)
Set MBR (Electromagnetic brake interlock) to available with the following servo parameters: [Pr. PD23 Output device
selection 1] to [Pr. PD26 Output device selection 4], [Pr. PD28 Output device selection 6], and [Pr. PD47 Output device
selection 7]. In addition, when the electromagnetic brake is placed in servo-off status, MBR and the base circuit both shut off
following a short delay. Set this delay time (Tb) in [Pr. PC16 Electromagnetic brake sequence output].
Page 133 When using the forced stop deceleration function
Servo
parameter
Symbol
Name
Outline
PC16
MBR
Electromagnetic brake sequence
output
Set the delay time used between the MBR (Electromagnetic brake interlock) shut-off
and the base circuit shut-off.
Initial value: 0 [ms]
PD23.0-1
*DO1
Device selection
Select a function of the CN3-22 pin.
PD24.0-1
*DO2
Device selection
Select a function of the CN3-23 pin.
PD25.0-1
*DO3
Device selection
Select a function of the CN3-24 pin.
PD26.0-1
*DO4
Device selection
Select a function of the CN3-25 pin.
PD28.0-1
*DO6
Device selection
Select a function of the CN3-49 pin.
PD47.0-1
*DO7
Device selection
Select a function of the CN3-13 pin.
PD47.2-3
*DO7
Device selection
Select a function of the CN3-14 pin.