250
9 MANUFACTURER FUNCTIONS
9.7 Internal torque limit selection
9.7
Internal torque limit selection
Device/parameter
The input devices and parameters are shown below.
• Input devices used in internal torque limit selection
• Parameters set in internal torque limit selection
Internal torque limit selection details
Positioning mode (point table method) and speed control mode (point table method)
Enabled torque limits are as follows.
Stopper type home position return
Enabled torque limits are as follows.
Device name
Description
CTL
Internal torque limit selection of input device
C_CTL
Control DI bit 8 (Internal torque limit selection)
PARAMETERS
Symbol
Description
Pr. PA11
TLP
Forward rotation torque limit
Pr. PA12
TLN
Reverse rotation torque limit
Pr. PC77
TL2
Internal torque limit 2
Pr. PT11
ZTT
Stopper type home position return torque limit value
Pr. PT48 (_ _ _ x)
TOP7A
Torque limit selection during stop
CTL and C_CTL
(Internal torque limit
selection)
Limit value status
Enabled torque limit value
CCW power running/CW
regeneration
CW power running/CCW
regeneration
All off
Pr. PA11
Pr. PA12
Either one on
Pr. PA11
Pr. PA12
Pr. PC77
Pr. PC77
CTL and C_CTL
(Internal torque limit
selection)
Limit value status
Enabled torque limit value
CCW power running/CW
regeneration
CW power running/CCW
regeneration
All off
Pr. PT11
Pr. PT11
Either one on
Pr. PC77 > Pr. PT11
Pr. PT11
Pr. PT11
Pr. PC77 < Pr. PT11
Pr. PC77
Pr. PC77
Pr. PC77 >
Pr. PA11
Pr. PA12
Pr. PC77 <
Pr. PA11
Pr. PA12