15 Factor Group Objects
15.1 [Polarity (Obj. 607Eh)]
105
15
15
Factor Group Objects
15.1
[Polarity (Obj. 607Eh)]
[Polarity (Obj. 607Eh: 00h)]
Description
The rotation direction selection can be set.
15.2
[Position encoder resolution (Obj. 608Fh)]
[Position encoder resolution (Obj. 608Fh: 00h)]
Description
The total number of Sub Indexes (= 2) is returned.
[Encoder increments (Obj. 608Fh: 01h)]
Description
The encoder resolution is returned. When the linear servo motor is connected, the virtual resolution per revolution is returned.
When the servo motor is used on a fully closed loop system configuration, the number of the load-side pulses of one
revolution of the servo-motor side is returned.
Writing a value triggers an error.
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RW
RXMAP
00h
00h to E0h
Possible
[Pr. PA14]
[Pr. PC29.3]
Bit
Description
0
reserved
1
reserved
2
reserved
3
reserved
4
reserved
5
0: Servo motor CCW rotation at positive torque
1: Servo motor CW rotation at positive torque
6
0: Servo motor CCW rotation at positive speed
1: Servo motor CW rotation at positive speed
7
0: Servo motor CCW rotation in the positioning address increase direction
1: Servo motor CW rotation in the positioning address increase direction
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
2
2 (fixed)
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RW
TXMAP
0 to 4294967295
inc
Impossible