214
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.7 MR-TB26A junction terminal block [WG]
6.7
MR-TB26A junction terminal block [WG]
Usage
Use the junction terminal block (MR-TB26A) with the junction terminal block cable (MR-TBNATBL_M) as a set. To use a
junction terminal block, mount it to the DIN rail.
The terminal numbers on a junction terminal block correspond with the pin numbers on the CN3 connector of a servo
amplifier. The terminal symbol S is for the shield.
Ground the junction terminal block cable using the S terminal of the junction terminal block.
Specifications
Item
MR-TB26A
Rating
AC/DC 32 V 0.5 A
Usable wires
Stranded wire
0.08 mm
2
to 1.5 mm
2
(AWG 28 to 14)
Solid wire
φ
0.32 mm to 1.2 mm
Wire insulator OD
φ
3.4 mm or less
Tool
210-619 (WAGO) or equivalent 210-119SB (WAGO) or equivalent
Stripped length
5 mm to 6 mm
Cable length
05: 0.5 m
1: 1 m
CN3
MR-TB26A
(MR-TBNATBL_M)
Servo amplifier
Junction terminal block
Junction terminal block cable