6 OPTIONS AND PERIPHERAL EQUIPMENT
6.5 PS7DW-20V14B-F junction terminal block (recommended) [G]
6.5
PS7DW-20V14B-F junction terminal block
(recommended) [G]
Usage
Use the junction terminal block (PS7DW-20V14B-F) with the option cable (MR-J2HBUS_M) as a set. A connection example is
shown below.
For MR-J2HBUS_M, ground the option cable on the junction terminal block side with the cable clamp fitting (AERSBAN-
ESET). For the use of the cable clamp fitting, refer to the following.
Page 244 Cable clamp fitting AERSBAN-_SET
Connection of MR-J2HBUS_M cable and junction terminal block
*1 Numbers in "_" indicate the cable length.
05: 0.5 m
1: 1 m
5: 5 m
*2 This signal can be used only on the MR-J5-_G_-RJ_.
PS7DW-20V14B-F
CN3
MR-J2HBUS_M
(AERSBAN-ESET)
Servo amplifier
Junction terminal block
Cable clamp
LSP
1
2
DOCOM
MO1
3
4
LZ
8
LB
7
9
SD
MR-J2HBUS_M
*1
INP
5
6
10
DICOM
LA
LG
LSN
11
12
MBR
MO2
13
14
LZR
18
LBR
17
19
DOG
15
16
20
EM2
ALM
LAR
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
LSP
DOCOM
MO1
LZ
LB
SD
INP
DICOM
LA
LG
LSN
MBR
MO2
LZR
LBR
DOG
EM2
ALM
LAR
E
CN3
PS7DW-20V14B-F
1
2
3
4
8
7
9
5
6
10
11
12
13
14
18
17
19
15
16
20
TPR2
*2
TPR1
*2
TPR2
*2
TPR1
*2
Junction terminal block
Servo amplifier
Terminal block
Shell
Shell
Shell
Shell
Connector: 52316-2019 (Molex)
Shell kit: 52370-2070 (Molex)