Cable clamp fitting AERSBAN-_SET
Generally, connecting the grounding of the shielded wire to the SD terminal of the connector provides a sufficient effect.
However, the effect can be increased when the shielded wire is connected directly to the grounding plate as shown below.
Install the grounding plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to expose the external
conductor, and press that part against the grounding plate with the cable clamp. If the cable is thin, clamp several cables in a
bunch.
The cable clamp comes as a set with the grounding plate.
• Dimensions
*1 Screw hole for grounding. Connect it to the grounding plate of the cabinet.
Model
A
B
C
Accessory fittings
AERSBAN-DSET
100
86
30
Clamp A: 2 pcs.
AERSBAN-ESET
70
56
Clamp B: 1 pc.
Clamp fitting
L
A
70
B
45
Cable clamp
(A, B)
Cable
[Unit: mm]
Earth plate
External conductor
Clamp section diagram
40
Strip the cable sheath of
the clamped area.
cutter
cable
Earth plate
M4 screw
*1
11
3
6
C
A
6
22
17.5
35
35
7
24
0
-0.2
B ± 0.3
2-
˳
5 hole
installation hole
Clamp section diagram
[Unit: mm]
L or less
10
30
24
+ 0.3
0