6 NORMAL GAIN ADJUSTMENT
6.2 One-touch tuning
235
6
One-touch tuning via a network
One-touch tuning via a network is available with servo amplifiers with software version A3 or later.
Using One-touch tuning mode (2D50h) allows one-touch tuning from a controller.
When a simple motion module RD77GF is used, the one-touch tuning is available with the servo transient transmission
function. For settings of the servo transient transmission function, refer to the controller instruction manual.
Related object (Servo transient transmission function)
Index
Sub
Object
Name
Data Type
Access
Default
Description
2D50h
0
VAR
One-touch tuning mode
U8
rw
0
One-touch tuning command
Setting a value of "1" to "3" starts one-touch
tuning. After one-touch tuning is
completed, the setting value automatically
changes to "0".
0: During one-touch tuning stop
1: Basic mode
2: High mode
3: Low mode
2D51h
0
VAR
One-touch tuning status
I8
ro
0
One-touch tuning status
Regardless of whether one-touch tuning is
properly completed or not, the setting value
changes to 100% at the completion.
Unit: %
2D52h
0
VAR
One-touch tuning Stop
U16
wo
0
One-touch tuning stop command
Writing "1EA5h" stops one-touch tuning.
2D53h
0
VAR
One-touch tuning Clear
U16
wo
0
The parameter changed in one-touch
tuning can be returned to the value before
the change.
0000h: Restores the initial value.
0001h: Restores the value before one-
touch tuning.
The setting value of the restored parameter
is stored to the EEP-ROM.
2D54h
0
VAR
One-touch tuning Error Code
U16
ro
0
One-touch tuning error code
0000h: Finished normally
C000h: Tuning canceled
C001h: Overshoot exceeded
C002h: Servo-off during tuning
C003h: Control mode error
C004h: Time-out
C005h: Load to motor inertia ratio
misestimated
C00Fh: One-touch tuning disabled
Summary of Contents for MELSERVO-J4 series
Page 2: ......
Page 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Page 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Page 645: ......