10 SETTING PARAMETERS
10.2 Setting Network Parameter
101
10
Network configuration setting
Set parameters of slave stations (slave station points, link device assignment) to the master station, and set link scan mode
and block data assurance per station.
This setting is available when "CC IE Field (Master Station)" is selected in the network setting.
Window
[View]
[Network Parameter]
"CC IE Field Number of Boards Setting" screen
"Network Configuration Setting"
Operating procedure
1.
Set the items on the screen.
Item
Description
Assignment Method
Select an assignment method for send range of each station.
Number of PLCs
Display the number of stations from 1 to total stations.
Station No.
Set the station number.
Setting range: 1 to 120
Station Type
Select the station type.
RX/RY Setting
Points
Specify the number of relay points on the link side.
Setting range:
• 16 to 2048 points for "Local Station" and "Intelligent Device Station"
• 16 to 128 points for "Remote Device Station", 16 to 64 points for "Remote I/O Station"
Start
Specify the start point of relay on the link side.
Setting range: 0 to 3FF0
End
Specify the end point of relay on the link side.
Setting range: F to 3FFF
RWw/RWr Setting
Points
Specify the number of registers on the link side.
Setting range:
• 4 to 1024 points for "Local Station" and "Intelligent Device Station"
• 4 to 64 points for "Remote Device Station"
Start
Specify the start point of register on the link side.
Setting range: 0 to 1FFC
End
Specify the end point of register on the link side.
Setting range: 3 to 1FFF
Reserved/Error Invalid Station
Set reserved stations and error invalid stations.
Alias
Set the alias.
Setting range: Up to 8 characters
Comment
Set the comment.
Setting range: Up to 32 characters
[Supplementary Setting] button
Displays the "Supplementary Setting" screen. (
Page 102 Supplementary setting)
[Equal Assignment] button
Displays the "Equal Assignment" screen. (
[Identical Point Assignment] button
Assigns the same link device points to all local stations.
Enter the points in the field next to the button.
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......