(3) PLC file
Parameters required for the files used in the CPU module are set.
*1: Not available for the Q00UJCPU.
Figure 8.3 PLC file
Table8.3 PLC file setting list
Item
Parameter
No.
Description
Setting range
Default
Reference
File register
*1
1100
H
Set a file for the file register used in
the program.
• Not used
• Use the same file name as the
program.
• Use the following file.
Not used
Transfer to Standard ROM at
Latch data backup operation
*1
1104
H
Select whether to batch-transfer
the data in the file register at the
time of latch data backup to the
standard ROM.
Checked/unchecked
Not selectable
Comment file used in a
command
1101
H
Set a file for device comments
used in the program.
• Not used
• Use the same file name as the
program.
• Use the following file.
Not used
-
Initial Device value
1102
H
Set a file for initial values of the
devices used for the CPU module.
• Not used
• Use the same file name as the
program.
• Use the following file.
Not used
File for local device
*1
1103
H
Set a file for local devices used in
the program.
• Not used
• Use the following file.
Not used
File use for SP.DEVST/S.DEVLD
instruction
1105
H
Set a device data file used for
writing to or reading from the
standard ROM.
• Not used
• Use the following file.
Not used